Design Wash 1400E™
©Elation Professional® 44 Design Wash 1400E™
single fixture or when multiple fixtures in stand-alone mode. See section 11.1
“Stand-Alone Operation” on page 34 for proper set-up instructions.
A Master unit can send up to 3 different data groups to the Slave units, i.e. a Master unit can
start 3 different Slave units, which run 3 different programs. The Master unit sends the 3
program parts in a continuous loop.
The Slave unit receives data from the Master unit according to the group which the Slave
unit was assigned to. If e.g. a Slave unit is set to “Slave 1” in the menu “Set to Slave”, the
Master unit sends “Auto Program Part 1” to the Slave unit. If set to “Slave 2”, the Slave unit
receives “Auto Program Part 2”.
To start a Auto Program please proceed as follows:
1. Slave-Setting
• Select “Function Mode” by turning the encoder.
• Press the Enter button to confirm.
• Select “Set to slave” by turning the encoder.
• Press the Enter button to confirm.
• Turn the encoder to select “Slave 1”, “Slave 2” or “Slave 3”.
• Press the Enter button to confirm.
• Press the Mode/Esc button in order to return to the main menu.
2. Automatic Program Run
• Select “Function Mode” by turning the encoder.
• Press the Enter button to confirm.
• Select “Auto Program” by turning the encoder.
• Press the Enter button to confirm.