Design Wash 1400E™
©Elation Professional® 54 Design Wash 1400E™
Dimmer Er
(Dimmer Shutters error) This message will appear after the reset of the fixture if the fixture’s
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). The dimmer flags are not
located in the default position after the reset.
Zoom Er
(Zoom motor error) This message will appear after the reset of the fixture if the fixture’s
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). The Step-less Zoom is not
located in the default position after the reset.
Fire Wheel Er
(Fire wheel error) This message will appear after the reset of the fixture if the fixture’s
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). The Fire wheel is not located
in the default position after the reset.