Transportation and Handling
The POWER SPOT 700 II™ comes with two carrying handles built into the base. Always
transport the fixture by these handles. Never lift or carry the POWER SPOT 700 II™ by the
yoke (head assembly) this can seriously damage the unit and will void your manufactures
warranty.
Connections
Power supply:
Electronic ballast with:
90~260 Volts, 50~60 Hz,
Grounded contact type plug – Neutrik Powercon
Connected load 1000W <=> 4.5 A (blind current compensation).
NOTE: The universal power supply will accept any voltage source as detailed above
without any type of internal or user modifications.
DMX:
USITT DMX 512 Standard input/output, 3 pole connectors.
[+] = Pin 3 / [-] = Pin 2 / [Ground] = Pin 1
Fuse Requirements:
The POWER SPOT 700 II’s electronic and lamp systems are protected by two GMA
(5x20mm) external fuses:
Lamp: 250v/10A (120v Operation) or 250v/5A (220v Operation)
Electronics: 250v/2A (120v Operation) or 250v/1A (220v Operation)
The fuse requirements are clearly printed on the side of the fixture.
• Always disconnect main power before changing the fuse!
• Always replace with the exact same type fuse unless otherwise specified by
an authorized Elation® service technician. Replacing with anything other than
the specified fuse can severely damage your fixture and will void your
manufactures warranty.