CONTRACTOR PRECISION SERIES

CPS2.9

Umains in V

Imains in A

Pmains in W

Pout in W

Pd in W1

BTU/hr2

 

Idle

230

0.4

46

0

46

157

 

 

 

 

 

 

 

 

 

Max. Output Power @ 8 Ω3

230

9.4

1740

1100

640

2184

 

Max. Output Power @ 4 Ω3

230

15.3

2810

1800

1010

3446

 

1/3 Max. Output Power @ 4 Ω3

230

8.7

1450

600

850

2900

 

1/8 Max. Output Power @ 4 Ω3

230

3.6

560

225

335

1143

 

1/8 Max. Output Power @ 4 Ω4

230

3.6

540

225

315

1075

 

1/8 Max. Output Power @ 4 Ω4 5

253

4.1

690

275

415

1416

 

Normal Mode (-10 dB) @ 4 Ω3

230

3.2

460

160

300

1024

 

Rated Output Power (0 dB) @ 4 Ω3

230

14.4

2640

1600

1040

3549

 

Alert (Alarm) Mode (-3 dB) @ 4 Ω3

230

10.2

1770

800

970

3310

 

Max. Output Power @ 2 Ω3

230

21.6

4090

2800

1290

4402

 

1/8 Max. Output Power @ 2 Ω3

230

5.1

850

350

500

1706

 

1/8 Max. Output Power @ 2 Ω4

230

5.0

810

350

460

1570

 

 

 

 

 

 

 

 

 

CPS2.12

Umains in V

Imains in A

Pmains in W

Pout in W

Pd in W1

BTU/hr2

 

Idle

230

0.5

57

0

57

194

 

 

 

 

 

 

 

 

 

Max. Output Power @ 8 Ω3

230

12.2

2100

1500

600

2047

 

Max. Output Power @ 4 Ω3

230

19.7

3620

2400

1220

4163

 

1/3 Max. Output Power @ 4 Ω3

230

11.2

1900

800

1100

3753

 

1/8 Max. Output Power @ 4 Ω3

230

4.7

720

300

420

1433

 

1/8 Max. Output Power @ 4 Ω4

230

4.7

705

300

405

1382

 

1/8 Max. Output Power @ 4 Ω4 5

253

5.3

880

375

505

1723

 

Normal Mode (-10 dB) @ 4 Ω3

230

4.1

625

220

405

1382

 

Rated Output Power (0 dB) @ 4 Ω3

230

18.9

3340

2200

1140

3890

 

Alert (Alarm) Mode (-3 dB) @ 4 Ω3

230

13.4

2330

1100

1230

4197

 

Max. Output Power @ 2 Ω3

230

27.5

5165

3600

1565

5340

 

1/8 Max. Output Power @ 2 Ω3

230

10.5

1810

450

1360

4640

 

1/8 Max. Output Power @ 2 Ω4

230

10.2

1730

450

1280

4368

 

Power consumption is direct proportional for other mains voltages. The following conversion factors are meant for easy conversion: 100V = 2.3; 120V = 1.9; 240V = 0.96

1)Pd = Power Dissipation

2)1 BTU = 1055.06 J = 1055.06 Ws

3)Sine Signal Modulation (1 kHz)

4)Pink Noise according to EN60065 / 7. Edition

5)10% Mains Over Voltage