Electrical installation
The electrical connection may only be performed by a qualified electrician/ competent person. The electrical connection must be carried out in accordance with prevailing regulations for appliances using heavy current. The connection must comply with any specific requirements specified by the local electricity supply authority.
There must be no interference with any of the unit’s electrical parts.
The cable is mounted in the terminal block as shown.
Unscrew the cover while connecting the cables.
More units may be connected via one or more junction boxes.
The cable must be connected via an external switch with a contact separation of at least 3 mm in each pole.
Please observe these instructions, otherwise the warranty will not cover any damage that may occur.
Cable type 1,5 mm²
The cable outside diameter must be between 7,5 and 10,5 mm.