Installation Requirements

5

 

 

Clearance requirements

IMPORTANT

DO NOT INSTALL YOUR WASHER:

1.In an area exposed to dripping water or out- side weather conditions. The ambient temper- ature should never be below 60° F (15.6° C) to maximize detergent effectiveness.

2.In an area (garage or garage-type building) where gasoline or other flammables (including automobiles) are kept or stored.

3.On carpet. Floor MUST be solid with a maxi- mum slope of 1 inch (2.54 cm). To minimize vibration or movement, reinforcement of the floor may be necessary.

INSTALLATION IN A RECESS OR CLOSET

If washer and dryer are installed in the same closet, door ventilation is required: A minimum of 120 square inches (774.2 cm²) of opening, equally divided at the top and bottom of the door, is required. Louvered openings should be located 3 inches (7.6 cm) from bottom and top of door. Air openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable.

3” (7.6cm)

60 sq. in.

(387.1cm²)

MINIMUM INSTALLATION CLEARANCES - Inches (cm)

SIDES REAR TOP FRONT

Alcove

0” (0 cm)

0” (0 cm)*

0” (0 cm)

n/a

 

 

 

 

 

Under-

0” (0 cm)

0” (0 cm)*

0” (0 cm)

n/a

Counter

 

 

 

 

 

 

 

 

 

Closet

0” (0 cm)

0” (0 cm)*

0” (0 cm)

1” (2.54 cm)

0” (0cm)

0”

(0cm)

1”

0”

(2.54cm)

(0cm)

60 sq. in.

(387.1cm²)

3” (7.6cm)

closet door

Page 5
Image 5
Electrolux 137067200, 137098000, 137019200, 137064300A, 134700400 Clearance requirements, Do not Install Your Washer