Problem | Possible cause | Remedy | |
| The transit packaging has | Remove the transit packag- | |
| not been removed. | ing. | |
The washing machine | The screw feet have not | Adjust the feet as described | |
in the installation and con- | |||
vibrates when operating | been correctly adjusted. | ||
nection instructions. | |||
or is unstable. |
| ||
|
| ||
| There is very little washing | Operation is not affected by | |
| in the drum (e.g. just one | ||
| this. | ||
| bathrobe). | ||
|
| ||
| The inlet hose screw con- | Tighten the inlet hose. | |
| nection is leaking. | ||
|
| ||
| The outlet hose is leaking. | Replace outlet hose. | |
Water is running out | The drain pump lid has not | Close the cover properly. | |
from under the washing | been closed properly. | ||
| |||
machine. | Washing was caught in the | Load washing carefully for | |
| |||
| door. | the next wash. | |
| The emergency drain hose is | Screw on the emergency | |
| leaking. | drain hose firmly. | |
| Too much detergent has | Follow the manufacturer's | |
There is a lot of foam. | |||
instructions exactly when | |||
probably been used. | |||
| measuring out detergent. | ||
|
| ||
| There is a kink in the outlet | Straighten the hose. | |
| hose. | ||
|
| ||
The END indicator is | The maximum pump height | Please contact your local | |
of 1m has been exceeded. | service centre. | ||
flashing twice, and si- | |||
|
| ||
multaneously an acous- |
| Switch off the appliance. | |
tic signal is sounding |
| ||
| Disconnect the power plug. | ||
twice. |
| ||
The drain pump is blocked. | Clean the drain pump. Re- | ||
(Problems with the wa- | |||
| move foreign bodies from | ||
ter outflow.) |
| ||
| the pump housing. | ||
|
| ||
| For sink spigot connections: | Clean the spigot. | |
| the spigot is blocked. | ||
|
| ||
Conditioner has not | The conditioner insert in the | Clean the detergent drawer, | |
been rinsed in, com- | |||
partment w for condi- | compartment for additives | insert the conditioner insert | |
has not been correctly in- | |||
tioner is filled with | firmly. | ||
serted or is blocked. | |||
water. |
| ||
|
| ||
|
|
|
19