Electrical Connection

Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.

1 WARNING – THIS APPLIANCE MUST BE EARTHED.

The manufacturer declines any liability should these safety measures not be observed.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance rating plate.

The appliance is supplied with a 13 amp plug fitted. In the event of having to change the fuse in the plug supplied, a 13 amp ASTA approved (BS 1362) fuse must be used.

Should the plug need to be replaced

for any reason, proceed as described below. The wires in the mains lead are

coloured in accordance with the following code:

Green and Yellow:

Earth

Blue:

Neutral

Brown:

Live

The wire coloured green and yellow

must be connected to the terminal marked with the letter “E“ or by the

earth symbol E or coloured green and yellow.

The wire coloured blue must be connected to the terminal “N“ or coloured black.

The wire coloured brown must be connected to the terminal marked “L“ or coloured red.

Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.

1WARNING! A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut off plug is disposed of safely.

28