Permanent Connection

In the case of a permanent connection it is necessary that you install a double pole switch between the appliance and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current electrical regulations.

The switch must not break the yellow and green earth cable at any point.

This appliance complies with the requirements laid out in the EEC Directive 76/899.

Voltage 240 V AC: Fuse rating 13amps See rating plate for further information. This appliance meets VDE requirements.

Particular regulations of local electricity authorities must be observed. This appliance conforms to EEC Directive No. 82/499/EWG on radio in- terference.

1 WARNING! Repairs to electrical appliances must only be carried out by trained personnel. Improper repairs may lead to serious risks for the us- er.

Connecting the appliance to the water supply

Important:

This appliance must not be connected to the hot water supply.

When connecting the appliance, use only new hose kits.

Only connect the appliance to the drinking water supply. Rain water or water for industrial use may only be used if it fulfils the require- ments of DIN1986 and DIN1988.

Do not kink or crush the water inlet hose or drain hose.

Permitted water pressure

The water pressure must be at least 1 bar (=10N/cm2 =0.1MPa), and may be a maximum of 10bar (=100N/cm2 =1MPa).

If more than 10bar: Connect a pressure reduction valve.

If less than 1bar: Disconnect the appliance end of the inlet hose from the solenoid inlet valve and remove the flow meter. (In addition re- move the filter using pointed pliers and take out the rubber gasket behind it.) Replace the filter.

29