17
C.2.4 DEFROSTING
If the appliance is in the right conditions (indicator light
or or with the appliance on standby), this function
enables a manual defrosting cycle. The display shows the
message “dEfr” throughout the entire cycle.
If a manual defrosting is not possible (during a chilling cycle) the
message “UTIL NONE” will appear on the display.
The selection is enabled only in preservation/maintenance and
when selecting the operating cycle.
When the defrosting is finished the system will go back to the
main configuration. The cycle times and the intervals between
defrostings are preset by the manufacturer.
- Manual defrosting
To start a manual defrosting, proceed as follows:
• PRESS THE BUTTON; THE DEFROSTING INDICATOR
LIGHT WILL TURN ORANGE, THE REST WILL STAY GREEN.
• PRESS AGAIN TO CONFIRM.
To shorten the defrosting time, the function can be run with the
door open, or a manual defrosting can be started with the chiller
door open; in this way the chiller internal fans will start up to draw
air into the chamber from the outside, thus shortening the
defrosting times.
For further information see following section.
MANUAL DEFROSTING
If the appliance is in the right conditions (indicator light
or or with the appliance on stand-by), this function
enables a manual defrosting cycle. The display shows the
message “dEfr” throughout the entire cycle.
If a manual defrosting is not possible (during a chilling cycle) the
message “UTIL NONE” will appear on the display.
The selection is enabled only in preservation/maintenance and
when selecting the operating cycle.
When the defrosting is finished the system will go back to the
main configuration.
Before each defrosting, remove the drain plug from the bottom
of the chamber. Replace the plug after defrosting.
C.2.5 GERMICIDAL LIGHTS (Function for appliances with
germicidal light option)
To enable the lights, the appliance must be switched on but with
no cycle running.
Press using the button to select the cycle.
The corresponding indicator light turns orange;
press the button again to confirm the selection and
start the cycle by pressing the button.
You are advised to run a germicidal cycle at the start of the day
before using the appliance, and another one at the end of the day
after cleaning the chamber.
For further information see sections B.1.5 and C.1.9.6.
ATTENTION: The cycle will not be enabled if the chamber
temperature is less than 59°F (15°C) or if the door is open.
THE EFFICIENT OPERATION OF THE APPLIANCE IN THE BLAST
CHILLING AND FREEZING CYCLES DEPENDS ON THE
FOLLOWING FACTORS:
C.2.6 PRODUCT LOADING AND UNLOADING
Use kitchen gloves when loading and unloading food. It is not
advisable to keep the food covered during the chilling cycle in
order to facilitate chilling. An even distribution of the food inside
the chamber allows good air circulation and therefore better
preservation of the food.
In any case, do not leave the door open longer than necessary
when removing or loading food.
At the end of the cycle, open the door and remove the probe,
putting it back in its original position (remember that the pans
are cold, therefore use gloves).
- Type of tray to be used. It is advised to use shallow trays (i.e.
with sides no higher than 2.5"/65 mm) to allow good air circulation
around the product (the greater the surface area of the food
exposed to the air, the shorter the chilling time). You are advised
to clean the trays and tray support surfaces thoroughly to avoid
food contamination. You are also advised to put the food in the
chiller in the same tray that it was cooked in.