18
C.2.7 INSERTING THE FOOD (CORE) PROBE IN THE PRODUCT
Make sure the probe is clean and sterilized whenever inserting
it in food, and always take care when handling the probe,
because it has a sharp point.
Using the food (core) probe in the chilling cycles guarantees
good results. To be certain of this, it is important to position the
probe correctly, i.e. right at the center of the largest piece of food,
making sure it doesn’t come out the other side and being very
careful not to touch the tray.
To get familiar with the chiller's electronic board as quickly as
possible, we have provided a series of step-by-step instructions
on how to enable the various functions.
When switched on, the appliance sets up for the SOFT chilling
cycle by default.
You can now select the cycle by pressing the button,
according to the following instructions:
-Hard chilling:
PRESS THE BUTTON UNTIL THE
LIGHT TURNS ORANGE
PRESS THE CYCLE BUTTON
IF THE PROBE HASN'T BEEN INSERTED IN THE PRODUCT,
THE CYCLE WILL BE TIMED.
-Hard chilling with chilling end time change:
PRESS THE BUTTON UNTIL THE
LIGHT TURNS ORANGE
IF YOU WANT TO CHANGE THE CHILLING END TIME
PRESS THE BUTTON FOR 2 SECONDS
PRESS THE BUTTON TO SELECT THE VALUE.
IF A SELECTION IS NOT MADE AFTER 5 SECONDS THE
LAST VALUE DISPLAYED WILL BE CONFIRMED
AUTOMATICALLYYOR YOU CAN CONFIRM BY
PRESSING THE BUTTON AGAIN.
PRESS THE CYCLE BUTTON
-Hard chilling with program select:
PRESS THE BUTTON UNTIL THE
LIGHT TURNS ORANGE
PRESS THE “SELECT PROGRAM” BUTTON
INDICATOR LIGHT LIGHTS UP
PRESS THE BUTTON UNTIL THE
THE INDICATOR LIGHT TURNS ORANGE
IF THE PROGRAM SELECTED IS OK
PRESS THE CYCLE BUTTON
C.3 STARTING THE OPERATING CYCLES