Instructions for the Installer
Engineers technical data
Overall dimensions
Width: | 740 mm. |
Depth: | 520 mm. |
Cut out dimensions
Width: | 560 mm. |
Depth: | 480 mm. |
Burner | Dia. Tap |
| 1/100 mm |
Auxiliary | 28 |
32 | |
Rapid | 40 |
Aeration adjustment none
Supply Connections
Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
Ignition HT Spark
Spark Generator: Ispra Control's BF 50066 -
Spark Gap : Fixed
Heat Input
Rapid Burner | 2.9 kW Natural Gas | |
| (9895 BTU/HR) |
|
| 2.7 kW L.P.G. |
|
| (9212 BTU/HR) |
|
Auxiliary Burner | 1.0 kW (3412 BTU/HR) | |
Appliance class |
| 3 |
Appliance category | II2H3+ | |
Gas supply | Natural gas G20 / 20mbar |
| BURNER | RAPID | AUXILIARY | |||||
TYPE OF GAS |
| (large) | (medium) | (small) | ||||
|
|
|
|
|
|
| ||
| POSITION | M A X | MIN | M A X | MIN | M A X | MIN | |
NATURAL GAS | NOMINAL THERMAL |
|
|
|
|
|
| |
POWER (kW) | 2.9 | 0.65 | 1.9 | 0.45 | 1.0 | 0.33 | ||
20 mbar | NOMINAL FLOW |
|
|
|
|
|
| |
VALUE = |
|
|
|
|
|
| ||
RATE (m3/h) | 0.276 | 0.062 | 0.181 | 0.043 | 0.095 | 0.028 | ||
37.78 MJ/m3 | ||||||||
Ws - 50.7 MJ/ m3 | NOZZLE REFERENCE | 119 | Adjust. | 96 | Adjust. | 70 | Adjust. | |
| (1/100 mm) |
|
|
|
|
|
| |
LPG GAS | NOMINAL THERMAL |
|
|
|
|
|
| |
POWER (kW) | 2.7 | 0.65 | 1.9 | 0.45 | 1.0 | 0.33 | ||
NOMINAL FLOW |
|
|
|
|
|
| ||
VALUE = |
|
|
|
|
|
| ||
RATE (g/h) | 195 | 46.8 | 137 | 32.4 | 72 | 23.8 | ||
49.92 MJ/Kg | ||||||||
|
|
|
|
|
|
| ||
| NOZZLE REFERENCE | 86 | 40 | 71 | 32 | 50 | 28 | |
| (1/100 mm) |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
11