11
Instructions for the Installer

Engineers technical data

BURNER RAPID SEMI-RAPID AUXILIARY
(large) (medi um) (small)
POSITION MA X MIN MA X MIN M AX MIN
NOMINAL THERMAL
POWER (kW) 2.9 0.65 1.9 0.45 1.0 0.33
NOMINAL FLOW
RATE (m3/h) 0.276 0.062 0.181 0.043 0.095 0.028
NOZZLE REFERENCE 119 Adjust. 96 Adjust. 70 Adjust.
(1/100 mm)
NOMINAL THERMAL
POWER (kW) 2.7 0.65 1.9 0.45 1.0 0.33
NOMINAL FLOW
RATE (g/h) 195 46.8 137 32.4 72 23.8
NOZZLE REFERENCE 86 40 71 32 50 28
(1/100 mm)
NATURAL GAS
20 mbar
VALUE =
37.78 MJ/m3
Ws - 50.7 MJ/ m3
TYPE OF GAS
LPG GAS
28-30/37 mbar
VALUE =
49.92 MJ/Kg
Burner Dia. Tap By-pass
1/100 mm
Auxiliary 28
Semi-rapid 32
Rapid 40
Aeration adjustment none

Supply Connections

Gas: RC 1/2 inch (1/2 inch male) Rear right
hand corner
Electric: 230-240V 50Hz supply, 3 core flexible
cable with non rewireable plug fitted with a 3 amp
cartridge fuse.

Ignition HT Spark

Spark Generator: Ispra Control's BF 50066 -
230-240V 0.6 YA T120
Spark Gap : Fixed

Overall dimensions

Width: 740 mm.
Depth: 520 mm.

Cut out dimensions

Width: 560 mm.
Depth: 480 mm.
Heat Input
Semi-rapid Burner 1.9 kW (6483 BTU/HR)
Rapid Burner 2.9 kW Natural Gas
(9895 BTU/HR)
2.7 kW L.P.G.
(9212 BTU/HR)
Auxiliary Burner 1.0 kW (3412 BTU/HR)
Appliance class 3
Appliance category II2H3+
Gas supply Natural gas G20 / 20mbar