Instructions for the Installer

Engineers technical data

Overall dimensions

Width:

740 mm.

Depth:

520 mm.

Cut out dimensions

Width:

560 mm.

Depth:

480 mm.

Burner

Dia. Tap By-pass

 

1/100 mm

Auxiliary

28

Semi-rapid

32

Rapid

40

Aeration adjustment none

Supply Connections

Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric: 230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

Ignition HT Spark

Spark Generator: Ispra Control's BF 50066 - 230-240V 0.6 YA T120

Spark Gap : Fixed

Heat Input

Semi-rapid Burner 1.9 kW (6483 BTU/HR)

Rapid Burner

2.9 kW Natural Gas

 

(9895 BTU/HR)

 

 

2.7 kW L.P.G.

 

 

(9212 BTU/HR)

 

Auxiliary Burner

1.0 kW (3412 BTU/HR)

Appliance class

 

3

Appliance category

II2H3+

Gas supply

Natural gas G20 / 20mbar

 

BURNER

RAPID

SEMI-RAPID

AUXILIARY

TYPE OF GAS

 

(large)

(medium)

(small)

 

 

 

 

 

 

 

 

POSITION

M A X

MIN

M A X

MIN

M A X

MIN

NATURAL GAS

NOMINAL THERMAL

 

 

 

 

 

 

POWER (kW)

2.9

0.65

1.9

0.45

1.0

0.33

20 mbar

NOMINAL FLOW

 

 

 

 

 

 

VALUE =

 

 

 

 

 

 

RATE (m3/h)

0.276

0.062

0.181

0.043

0.095

0.028

37.78 MJ/m3

Ws - 50.7 MJ/ m3

NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

 

(1/100 mm)

 

 

 

 

 

 

LPG GAS

NOMINAL THERMAL

 

 

 

 

 

 

POWER (kW)

2.7

0.65

1.9

0.45

1.0

0.33

28-30/37 mbar

NOMINAL FLOW

 

 

 

 

 

 

VALUE =

 

 

 

 

 

 

RATE (g/h)

195

46.8

137

32.4

72

23.8

49.92 MJ/Kg

 

 

 

 

 

 

 

 

NOZZLE REFERENCE

86

40

71

32

50

28

 

(1/100 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Page 11
Image 11
Electrolux 95752 G manual Instructions for the Installer, Engineers technical data