Installing the appliance

Transportation, unpacking

It is recommended to deliver the appliance in its
original packaging, in a vertical position.
After each transportation the appliance must not be
switched on for approx. 2 hours.
Unpack the appliance and check if there are damages on
it. Report possible damages immediately to the place of
purchase. In which case retain packaging.

Cleaning

Remove any adhesive tape, which ensure the parts do not
move in the appliance.
Wash the inside of the appliance using lukewarm water and
mild detergent. Use soft cloth.
After cleaning wipe out the inside of the appliance.

Placement

The ambient temperature has an effect on the energy
consumption and proper operation of the appliance. When
placing, take into consideration that it is practical to
operate the appliance between ambient temperature limits
according to the climate class that is given in the chart
below and can be found in the rating plate.
If the ambient temperature goes below the lower data the
temperature of the cooling compartment can go beyond
the prescribed temperature.
If the ambient temperature goes beyond the upper data
this means longer operating time of the compressor,
increasing temperature in the freezer or increasing energy
consumption.
When placing the appliance ensure that it stands level. This
can be achieved by the two adjustable feet (1) bottom
front two. 1-1 piece of distance washers (2) are accessories
of the adjustable feet. When levelling the appliance if
necessary, these washers can be removed.
Do not stand the appliance on a sunny place or close to a
radiator or cooker.
The refrigerator is designed to operate when it is totally
pushed to the wall.
When placing the refrigerator keep minimal
distances recommended in figure.
A: placing it under a wall-cupboard
B: placing it freely
GB
2
1

Class of climate

SN

N

ST

Ambient temperature

+10 ... +32 °C

+16 ... +32 °C

+18 ... + 38 °C

Instructions for the Installer
Model
Gross capacity (l)
Net capacity (l)
Width (mm)
Height (mm)
Depth (mm)
Energy consumption (kWh/day)
(kWh/year)
Energy class, according to EU Standards
Freezing capacity (kg/24h)
Rising time (h)
Rated current (A)
Weight (kg)

Technical data

A 75108 GA3
100
80
595
850
635
0,575
210
A
9
13
0.5
40