Installation Instructions
71
Electrical Connection
The oven is designed to be connected to 230-240V (50Hz) electricity
supply
The oven has an easily accessible terminal block which is marked as
follows.
Letter L - Live terminal
Letter N - Neutral terminal
or E - Earth terminal
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical supply must com-
ply to the specifications given below..
It is necessary that you install a double pole switch between the oven
and the electricity supply (mains), with a minimum gap of 3mm bet-
ween the switch contacts and of a type suitable for the required load in
compliance with the current rules.
The switch must not break the yellow and green earth cable at any
point.
Important
After installation and connecting, the cable must be placed so that it
cannot at any point reach a temperature of more than 60°C above the
ambient temperature.
Before the oven is connected, check that the main fuse and the dome-
stic installation can support the load, and that the power supply is pro-
perly earthed.
The manufacturer disclaims any responsibility should these safety mea-
sures not be carried out.
Connection via Min. size
Cable/Flex
Cable/Flex
type Fuse
Cooker control
circuit 6mm2PVC/PVC twin
and earth 20A