TECHNICAL DATA

DIMENSIONS

 

Height

Width

Depth

Height to hotplate

900mm (nominal)

550mm (nominal)

600mm

 

 

 

(to front of

 

 

 

door panel)

Space for fixing at hotplate level

2mm minimum clearance

 

 

Space for fixing above hotplate level

Flush-see important note 'Location of Appliance' page 36.

Minimum space above hotplate

787mm (If a cooker hood is fitted refer to the cooker hood

 

installation instructions).

 

 

Weight of appliance

62.0kg.

 

 

Minimum distance from rear wall

5mm (spacer given by pressed spacer on vent panel).

CONNECTIONS

Gas

Rear left hand side of appliance at hotplate level.

 

Rc½ (½" B.S.P. female).

 

 

Electric

None

 

 

 

GRILL

Natural Gas

 

L.P.Gas

 

Heat Input

2.7kW (9215 Btu/h)

2.45kW (176 g/h)

Injector Marking

121

 

078

 

HOTPLATE

 

Natural Gas

 

 

R.H.F.

R.H.R.

L.H.R.

L.H.F

Heat Input

1.0kW

1.9kW

1.9kW

2.9kW

 

(3412 Btu/h)

(6483 Btu/h)

(6483 Btu/h)

(9895 Btu/h)

Injector Marking

070

096

096

119

 

 

L.P.Gas

 

 

R.H.F.

R.H.R.

L.H.R.

L.H.F.

Heat Input

1.0kW

1.9kW

1.9kW

2.8kW

 

(71.85 g/h)

(136.5 g/h)

(136.5 g/h)

(194 g/h)

Injector Marking

050

071

071

086