CONNECTION TO ELECTRICITYSUPPLY
This appliance must be connected to a isolated
220V-240V a.c. 50Hz supply which
incorporates a 3 ampere fuse. If any other type
of plug is used it should incorporate a 5 ampere
fuse in either the plug or adapter or at the
distribution board. The appliance is supplied
with 2 metres (6.5 ft) of 5 ampere 3 core cable
fitted with a moulded plug. If this proves
insufficient to allow the appliance to be plugged
into the nearest supply socket, the supply cable
can be either extended by using a B.E.A.B.
approved 3-way sealed flex connector with
integral flex clamps.
DO NOT EXTEND THE CABLE USING
PLASTIC OR CERAMIC CONNECTION
TERMINAL BLOCKS AND/OR INSULATION
TAPE.
Should the supplied cable be required to be
threaded through small apertures in the
cabinets it can be removed from the mains
plug.
If the supplied moulded plug is cut off
dispose of it safely as it will be a shock
hazard if inserted into a 13 amp socket
elsewhere in the house.
To fit a 3 pin 13 amp plug to the end of the
appliance cable (Fig.9). Connect the wires as
follows:
BROWN to the live terminal.
BLUE to the neutral terminal.
GREEN / YELLOW to the earth terminal.
45
INSTALLATION INSTRUCTIONS
WARNING: This appliance must be
earthed, do not earth this appliance
to the gas supply piping.
GREEN / YELLOW
3 AMP
BROWN
BLUE
Fig.9