TECHNICAL DETAILS

DIMENSIONS

Height:

900 mm (nominal)

Width:

500 mm (nominal)

Depth:

600 mm (to front of door panel)

Weight:

54 .4 Kg Net

Space for fixing at hotplate level 2mm minimum clearance

Space for fixing above hotplate level. See important note 'Location of Appliance'.

Minimum space above hotplate 750mm (If cooker hood is fitted refer to the cooker hood installation instructions.

Minimum distance from rear wall 5mm (spacer given by pressed spacer on vent panel)

CONNECTIONS

 

 

 

 

Gas connection: -

Rear left hand side of appliance at hotplate level

 

 

Rc ½ (½” B.S.P. female)

 

 

Electrical connection: -

None

 

 

 

IGNITION

Battery 1.5 Volt AA size

 

 

HOTPLATE

 

 

 

 

 

Natural Gas

 

 

 

Heat Input

R.H.F

R.H.F

L.H.R

L.H.F

 

1.0kW

1.9kW

1.9kW

2.9kW

 

(3412 Btu/h)

(6483 Btu/h)

(6483 Btu/h)

(9895 Btu/h)

Injector Marking

070

096

096

119

 

L.P.Gas

 

 

 

Heat Input

1.0kW

1.9kW

1.9kW

2.8kW

 

(71.8g/h)

(136.5g/h)

(136.5g/h)

(194.0g/h)

Injector Marking

050

071

071

086

GRILL

Natural Gas

 

L.P.Gas

 

Heat Input

2.7kW (9215 Btu/h)

2.7kW (176g/h)

 

Injector Marking

121

 

78

 

SECOND OVEN

 

 

 

 

Heat Input

2.4kW (8189 Btu/h)

2.4kW (172.4g/h)

Injector Marking

108

 

078

 

Dual Control By-Pass

Fixed Internal

 

Fixed Internal

 

MAIN OVEN

 

 

 

 

Heat Input

2.4kW (8189Btu/h)

2.4kW ( 172.4g/h)

Injector Marking

108

 

78

 

Thermostat By-Pass Marking

69

 

48

 

GENERAL

 

 

 

 

Ignition

(H.T. Spark)

 

 

 

Spark Gap

3-4mm

 

 

 

GAS CATEGORY COUNTRIES OF DESTINATION

 

 

 

CAT. I2H

GB

 

 

 

CAT. I3+

GB

 

 

 

This appliance complies with: European Council Directives Low voltage Directive 73/23/EEC ,Gas Directive 90/396/EEC EMC Directive 89/336/EEC, CE Marking Directive 93/68/EEC.

27

Page 27
Image 27
Electrolux EKG5046, EKG5047 manual Technical Details