![](/images/new-backgrounds/1059460/5946027x1.webp)
Instructions for the installer
3.8Gas regulations
If the cooking appliance is set up for a different type of gas than that available, its injectors must be replaced, the minimum flow regulated. In order to replace the injectors in the cooking hob, it is necessary to carry out the following operations:
ξremove the pan supports;
ξremove the burners and burner caps (Fig. A);
ξtake out the injector (Fig. B) and replace it with one
suitable for the new type of gas (see "GENERAL
INJECTORS TABLE");
ξreplace the gas label (on the rear of the appliance) with the new one provided with the injectors kit;
ξrefit all parts by following the disassembly instructions in reverse order and taking care to position the burner cap correctly on the burner.
3.8.1Minimum flow of valved cooking hob taps
ξSwitch on the burner and turn the control knob towards the minimum flow position ;
ξremove the knob;
ξusing a screwdriver, adjust the internal screw Z until the correct low flame is obtained;
ξrefit the knob.
3.8.2Minimum flow of non-valved cooking hob taps
ξSwitch on the burner and turn the control knob towards the minimum flow position ;
ξremove the knob;
ξinsert a small screwdriver into the rod of the tap and adjust the internal screw Z until the correct low flame is obtained;
ξrefit the knob.
ξUnscrew the adjustment screw Z to increase the flow, or tighten it to reduce the flow.
ξThe adjustment is correct when the low flame measures approximately 3 or 4 mm.
ξWhen changing quickly from maximum to minimum flow and vice versa make sure that the flame does not go out.
GENERAL INJECTORS TABLE
TYPE OF GAS
mBar | NOZZLE NO. | BURNERS | |
POSITION TYPE | |||
|
|
POWER Watt |
| CONSUMPTION | ||
|
|
|
|
|
MAX. |
| MIN. |
| MAX. |
NATURAL GAS
LPG
BUTANE
PROPANE
20 |
30
28
37
115 |
| RAPID |
|
|
|
97 |
| SEMI RAPID |
|
|
|
72 |
| AUXILIARY |
|
|
|
128 |
| |
|
|
|
94 |
| FISH KETTLE |
|
|
|
85 |
| RAPID |
|
|
|
65 |
| SEMI RAPID |
|
|
|
50 |
| AUXILIARY |
|
|
|
93 |
| |
|
|
|
68 |
| FISH KETTLE |
3000 | 750 | 286 l/h |
1750 | 480 | 167 l/h |
1000 | 330 | 95 l/h |
3300 | 1300 | 314 l/h |
1900 | 750 | 181 l/h |
3000 | 750 | 219 g/h |
1750 | 480 | 128 g/h |
1000 | 330 | 73 g/h |
3300 | 1300 | 241 g/h |
1900 | 750 | 138 g/h |
3.9Connecting to LPG
Use a pressure regulator and connect to the cylinder in compliance with the guidelines set out in standards regulations in force.
14