Electrolux EOU43003 user manual Anti-shock protection must be provided by the installation

Models: EOU43003

1 24
Download 24 pages 60.4 Kb
Page 19
Image 19
•Anti-shock protection must be provided by the installation.

Suitable isolation devices include, for ex- ample, circuit breakers, fuses (screw type fuses are to be removed from the holder), RCDs and contactors.

Anti-shock protection must be provided by the installation.

The built-in unit must meet the stability re- quirements of DIN 68930.

Built-in cookers and cooking surfaces are equipped with special attachment sys- tems. For safety reasons, they must only

electrolux 19

be combined with appliances from the same manufacturer.

The use of heat protection strips is prohibited for cookers and ovens with Pyrolytic Clean- ing, if the recess has a rear wall and closed ground-level compartment.

However installation is possible with a ground-level compartment that has been shortened by at least 20 mm and which has base ventilation of the same cross-section.

40mm

320mm

320 mm

90°

90°

364 mmManual background

551 mm

720 mm

560 mm

15x

2x

2x

Page 19