hints for test institutes electrolux 37

Hints for test institutes

Testing in accordance with EN 60704 must be carried out with appliance fully loaded and using the test programme (see "Consumption values").

Test in accordance with EN 50242 must be carried out when the salt container and rinse aid dispenser have been filled with salt and rinse aid respectively and using the test programme (see "Consumption values").

Full load: 12 standard place settings

Amount of detergent required:

Rinse aid setting:

5 g + 25 g (Type B)

position 4 (Type III)

Arrangement upper basket (take off the glass holder)

Arrangement cutlery

basket

Arrangement lower basket

Cup racks: position 2

Page 37
Image 37
Electrolux ESL 68500 user manual Hints for test institutes, Full load 12 standard place settings