Important instructions for the installer
General
The instantaneous water heater is manufactured and tested in conformity with the valid IEC specifications and DIN standards. The appliance complies with the Appliance Safety Act. The indications given on the rating plate, the technical connection specifications of the electricity and water companies in the geographical area concerned, and VDE 0100 and DIN 1988 must be observed when the appliance is being installed.
The specific resistance of the water at the installation site should not be less than 1100 Ωcm.
This appliance complies with the following EC Directives:
-the
-the”Electromagnetic Compatibility” Directive 89/336/EEC of 03.05.1989 including Amendment Directive 92/31/EEC
Appliance constitution
1 | 2 | 3 |
| 4 |
14 | 5 |
| |
| 6 |
4a | 7 |
|
13 |
| 8 |
|
| |
|
| 9 |
|
| 10 |
| 3a | 11 |
12 |
|
1 =Back wall
2 =Quick fastener for appliance mounting
3=Upper cable bushing
3a = Lower cable bushing
4 =Upper mains connection terminal
5 =Flowrate sensor
6 =Safety temperature and pressure limiter
7 =Electronic module
8 =Temperature selector knob
9 =Flowrate limiter
10 =Strainer insert
11 = Cold water connection
12 =Hot water connection
13 =Thermostat
14 =Heating block
5