12 Installing the hood
Making the electrical connections
Electrical Shock Hazard
Warning: Turn off power at the service panel before wiring this unit.
120 V AC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GROUND THE APPLIANCE. TO PROTECT YOU AGAINST ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE MUST BE CONNECTED TO THE GROUNDING WIRE IN YOUR HOME ELECTRICAL SYSTEM, AND IT MUST UNDER NO CIRCUMSTANCES BE CUT OR REMOVED.
Failure to do so can result in death or electrical shock.
Remove junction box cover and knockout on the top left side.
Knockout
Junction box cover
If not already done, install 1/2” conduit connector in
NOTE: This connector is not included with vent hood.
Metal electrical conduit
House wiring
UL listed wire nut
Run black (live), white (neutral), and green (earth) wires (#14 AWG) according to the National Electrical Code or CSA Standards and local codes and ordinances in 1/2” conduit from power supply to
Connect black, white, and green wires from power supply to black, white, and green/yellow wires in
These connections should be done while always making reference to the electrical diagram found inside the hood.
Close