Electrolux RH30WC55GSB manual Installing the hood, Making the electrical connections

Models: RH30WC55GSB

1 21
Download 21 pages 8.74 Kb
Page 12
Image 12
12 Installing the hood

12 Installing the hood

Making the electrical connections

Electrical Shock Hazard

Warning: Turn off power at the service panel before wiring this unit.

120 V AC, 15 or 20 Amp circuit required.

ELECTRICAL GROUNDING INSTRUCTIONS

THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GROUND THE APPLIANCE. TO PROTECT YOU AGAINST ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE MUST BE CONNECTED TO THE GROUNDING WIRE IN YOUR HOME ELECTRICAL SYSTEM, AND IT MUST UNDER NO CIRCUMSTANCES BE CUT OR REMOVED.

Failure to do so can result in death or electrical shock.

Remove junction box cover and knockout on the top left side.

Knockout

Junction box cover

If not already done, install 1/2” conduit connector in j-box.

NOTE: This connector is not included with vent hood.

Metal electrical conduit

House wiring

UL listed wire nut

Run black (live), white (neutral), and green (earth) wires (#14 AWG) according to the National Electrical Code or CSA Standards and local codes and ordinances in 1/2” conduit from power supply to j-box.

Connect black, white, and green wires from power supply to black, white, and green/yellow wires in j-box respectively.

These connections should be done while always making reference to the electrical diagram found inside the hood.

Close j-box cover and reapply