Important safety Instructions - Electrical & Installation

Important safety Instructions - Electrical & Installation

5

requirements

 

READ AND SAVE THESE INSTRUCTIONS

 

Electrical & Installation requirements

 

 

 

Electrical requirements

IMPORTANT

Observe all governing codes and ordinances.

It is the customer’s responsibility:

To contact a quali"ed electrical installer.

To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and

C22.2 No.0-M91 - latest edition** and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a quali"ed electrician determine that the ground path is adequate.

Do not ground to a gas pipe.

Check with a quali"ed electrician if you are not sure range hood is properly grounded.

Do not have a fuse in the neutral or ground circuit.

IMPORTANT

Save Installation Instructions for electrical inspector’s use.

The range hood must be connected with copper wire only.

The range hood should be connected directly to the fused disconnect (Or circuit breaker) box through metal electrical conduit.

Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 — latest edi- tion*, or CSA Standards C22.1-94, Canadian Electri- cal Code Part 1 and C22.2 No. 0-M91 - latest edi- tion** and all local codes and ordinances.

A U.L.- or C.S.A.-listed conduit connector must be provided at each end of the power supply conduit (at the range hood and at the junction box).

Copies of the standards listed may be obtained from:

*National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269

**CSA International 8501 East Pleasant Valley Road Cleve- land, Ohio 44131-5575

Before installing the hood

1.For the most e#cient air $ow exhaust, use a straight run or as few elbows as possible.

Vent unit to outside of building, only.

2.At least two people are necessary for installation.

3.The hood is "tted with Screws and Drywall Anchors suitable for most surfaces, consult a Quali"ed Installer, check if they perfectly "t with your cabinet/wall.

4.Do not use $ex ducting.

5.COLD WEATHER installations should have an additional backdraft damper installed to minimize backward cold air $ow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork. The damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the ducting enters the heated portion of the house.

6.Make up air: Local building codes may require the use of Make-Up Air Systems when using Ducted Ventilation Systems greater than speci"ed CFM of air movement.

The speci"ed CFM varies from locale to locale. Consult your HVAC professional for speci"c requirements in your area.