14
Heavy build up of frost, pos-
sibly also on the door seal.
Door seal is not air tight
(possibly after changing
over the hinges).
Carefully warm the leaking
sections of the door seal
with a hair dryer (not hotter
than approx. 50 ¡C). At the
same time shape the war-
med door seal by hand such
that it sits correctly.
Unusual noises.
The appliance is touching
the wall or other objects.
Appliance is not level.
A component, e.g. a pipe,
on the rear of the appliance
is touching another part of
the appliance or the wall.
The compressor starts after
a period of time.
See the "Cleaning and
Care" section.
This is normal, no error has
occurred.
The compressor does not
start immediately after chan-
ging the temperature set-
ting.
Water on the floor or on sto-
rage shelves.
Water drain hole is blocked.
If necessary, carefully bend
the component out of the
way.
Move the appliance slightly.
Readjust the feet.
Changing the light bulbWarning! There is a risk of electric shocks! Before changing the light
bulb, switch off the appliance and unplug it, or pull the fuse or the cir-
cuit breaker. Light bulb data: 220-240 V, max. 15 W
If, after carrying out the necessary checks there is still a fault with
your appliance please contact your local AEG Service Force Centre.
In guarantee customers should ensure that the suggested
checks have been made as the engineer will make a charge if the
fault is not a mechanical or electrical breakdown.
Please note that proof of purchase is required for any in-guarantee
service calls.