Installation
The Refrigerator needs Ventilation
Air is fed under the door through the vent
slots in the base and is exhausted upwards along the back wall. To ensure proper air circulation never cover or alter the vent
openings.
Important! If the appliance is installed under a hanging cabinet, a clearance of at least 10 cm between the top of the appliance and the cabinet above it must be maintained.
Please check whether, after installing your appliance and especially after reversing the
door, the door seal fits tightly. A badly fitting door seal may lead to heavy frosting
and a higher power consumption (see also "Something not working“).
Appliance Alignment
01. The appliance must be level, please compensate for unevenness in the floor by turning the two adjustable feet at the front.
When two appliances are placed beside each other, the spacers enclosed in the plastic wrapping should be glued between the appli- ances as shown in the illustration.
10 | 818 35 |