Vermont Casting 2160 Sequoia Clearance Chart, Stove Clearance, Unprotected Surfaces, 2001049

Models: 2160

1 34
Download 34 pages 58.99 Kb
Page 12
Image 12
Sequoia Clearance Chart

Dutchwest Sequoia

Sequoia Clearance Chart

 

 

 

Stove Clearance

 

 

 

 

 

 

 

Unprotected Surfaces

 

Protected Surfaces

 

 

 

 

 

 

 

 

 

Stove Installed

Stove

 

Stove Installed

Stove

 

in

 

in

 

Parallel to Wall

 

Parallel to Wall

 

Corner

 

Corner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Side

Rear

Corners

 

Side

Rear

Corners

 

 

 

 

 

 

 

 

No stove

(A) 32”

(B) 42”

(C) 36”

 

(D) 16”

(E) 26”

(F) 20”

heat shields1

(813mm)

(1067mm)

(914mm)

 

(406mm)

(660mm)

(508mm)

 

 

 

 

 

 

 

 

Stove, top exit with rear

(G) 32”

(H) 42”

(I) 36”

 

(J) 16”

(K) 26”

(L) 20”

heat shield, no connector

 

(813mm)

(1067mm)

(914mm)

 

(406mm)

(660mm)

(508mm)

heat shields

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stove, top exit with rear

(M) 32”

(N) 20”

(O) 26”

 

(P) 16”

(Q) 14”

(R) 12”

heat shield, and heat

 

(813mm)

(508mm)

(660mm)

 

(406mm)

(356mm)

(305mm)

shields on connector1,2,3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stove, rear exit with rear

(S) 32”

(T) 20”

N/A

 

(U) 16”

(V) 14”

N/A

heat shield only

(813mm)

(508mm)

 

 

(406mm)

(356mm)

 

 

 

 

 

 

 

 

Chimney Connector Clearance

 

 

 

 

 

 

Unprotected Vertical Surfaces

 

Protected Vertical Surfaces

No chimney connector

 

36” (914mm)

 

 

 

19” (483mm)

 

heat shields

 

 

 

 

 

 

 

Chimney connector

 

14” (356mm)

 

 

 

8” (203mm)

 

heat shields installed2

 

 

 

 

 

 

 

 

 

 

 

 

Clearance to Combustibles in Front of Stove

 

 

 

 

 

 

 

 

All Installations

48” (1219mm)

 

 

 

 

 

 

 

 

 

1 All installations venting straight up to a factory-built chimney require a 24” (610mm) diameter or square ceiling heat shield. The ceiling heat shield should be 24 gauge sheet metal or equivalent mounted on 1” (25mm) noncombustible spacers 1” (25mm) below ceiling.

2 Shielding for a top exit stove must include a shield insert to protect the area behind the flue collar.

3 Chimney connector heat shields must extend to within 1” (25mm) or less of the ceiling heat shield for installations venting straight up to a factory-built chimney. Top exit installations using an elbow to vent to rear chimney connector must be shielded over entire vertical length.

12

2001049

Page 12
Image 12
Vermont Casting 2160 Sequoia Clearance Chart, Stove Clearance, Unprotected Surfaces, Protected Surfaces, Dutchwest Sequoia