Vermont Casting 2160 Fireplace Installations Above the Fireplace, Dutchwest Sequoia, 2001049

Models: 2160

1 34
Download 34 pages 58.99 Kb
Page 7
Image 7
Fireplace Installations -

A special piece called the "thimble sleeve," slightly smaller in diameter than the standard connector and most thimbles, will ease the removal of the chimney connector system for inspection and cleaning. (Fig. 6) Thimble sleeves should be available from your local dealer.

 

Thimble

 

Sleeve

 

Flue

Elbow

Thimble

 

Keep

 

Sleeve

 

End Flush

 

with Flue

 

Tile

Chimney

 

Connector

 

Flue Liner

ST243

Fig. 7 The thimble, made of either ceramic or metal, must be cemented in place securely.

To install a thimble sleeve, slide it into the breech until it is flush with the inner flue wall. Do not extend it into the actual flue passage, as that could interfere with the draft.

The thimble sleeve should protrude 1-2" (25-50 mm) into the room. Use furnace cement and thin gasketing to seal the sleeve in place in the thimble. Secure the chimney connector to the outer end of the sleeve with sheet metal screws.

Fireplace Installations -

Above the Fireplace

In this installation, the chimney connector rises from the stove, turns ninety degrees, and goes back into the fireplace chimney. The liner of the fireplace chimney should extend at least to the point at which the chim- ney connector enters the chimney. Follow all the guidelines for installing a chimney connector into a freestanding masonry chimney, and pay special attention to these additional points:

Check the stove and chimney connector clearances to combustible mantel or trim materials. Use the necessary combination of mantel, trim, and connec- tor heat shields to provide the required clearances. (Fig. 8)

Double-check connector clearance from the ceiling.

The fireplace damper must be closed and sealed to prevent room air from being drawn up the flue, reducing the draft. However, it must be possible to re-open the damper to inspect or clean the chimney.

Dutchwest Sequoia

24"

(610mm)

Chimney

Connector Shield

Block-Off Plate

Chimney Connector

ST244b

Fig. 8 The connector enters flue above the fireplace. If the clearance between the chimney connector and either the mantel and/or the ceiling is inadequate, special protective shields will be required.

Fireplace Installations -

Through the Fireplace

If the height of your fireplace opening is at least 30” (762mm), you may install a Sequoia through the opening using a “positive connection” kit available from your local dealer. These kits ensure a tight fit between the stove flue collar and the chimney flue.

Fireplace installations, whether connected to the flue above or through the fireplace opening, have special clearance requirements to adjacent trim and the mantel. You will find the required safe clearances for Sequoia fireplace installation on Page 10.

Floor protection requirements also apply to fireplace installation. Be sure to review the floor protection requirements on Page 8.

Flue Liner

 

Extend Chimney

 

Connector to the First

Damper

Tile of the Flue Liner

Plate is

 

 

Remvoed

 

or Locked

Observe

in Open

Position

Miniumum Clearances

 

 

Close Off the

Fireplace

Damper

Opening with

Adapter Kit

Sheet Metal

 

ST245a

and Sealant

 

Fig. 9 The connector passes through the fireplace to enter flue. Special Fireplace Adapter Kits to simplify fireplace installations are available from your local dealer.

2001049

7

Page 7
Image 7
Vermont Casting 2160 Fireplace Installations Above the Fireplace, Fireplace Installations Through the Fireplace, 2001049