Features and Specifications
APPLICATION:
The ELK-M1XEPis an Ethernet Device Server with a RS-232 Serial Port Interface. It may be used to connect a Control in the M1 Family to an Ethernet network using TCP-IP protocol. It features a secure embedded web server, with a user interface built on a Java applet, email event notification, and FIPS compliant encryption algorithms for security sensitive environments. It is powered by an ELK-P1216 12 Volts DC, 1.5 Amp plug-in power supply/adapter (included). A software setup utility is built into ElkRP (version 1.5.0 or later) for configuring the connection setup, network password, etc. The M1XEP is factory defaulted to obtain a dynamic IP address from a DHCP server (i.e. Ethernet switch, cable modem, etc.), however it may also be setup with a static IP address.
FEATURES:
•Web server with embedded Java applet "M1 Virtual Keypad"
•Secure connection with password protection and HTTPS encryption
•Flash Memory for Firmware Updating
•Event notification via E-Mail (SMTP)
•Internet Monitoring and Reporting Capability
•URL Updating using Dynamic DNS
•TCP/IP stack supporting the following protocols: TCP,UDP,DHCP,SSL 3.0/TLS 1.0, HTTP, SMTP
•Federal Information Processing Standards (FIPS) 128 bit encryption
•Integrated 802.3 compliant 10/100 Mbit network interface
•RS232, DB9M 9-pin serial port connection
•Connects to the M1 RS-232 Serial port (Port 0) The baud rate for this port must be set to 115,200 (factory default)
•RJ45 8-pin Network Jack
•2.1mm barrel type power connector (center positive)
•LED Indicators for Power, Link, and Data
SPECIFICATIONS:
•Operating Voltage: 12 Volts D.C. from Elk-P1216 Plug-in Power Supply **
•Current Draw: approx. 300 mA
•Housing Dimensions: 4.25" x 6.375" x 2.125"
•Circuit Board Dimensions: 2.25" x 3.95"
**Any required network equipment, i.e. Ethernet switch, router, cable modem, etc. including the plug-in power supply for the M1XEP, MUST be backed up with an adequately sized UPS (Uninterruptible Power Supply) in order for the equipment to continue operating during brief power outages.
| RJ-45 Connector | Description | Normal State |
| LED Indicators |
| | |
| | | |
| Orange | Processor Power Indicator | On-Solid |
| | | |
| Green | Network Traffic Indicator | On-Blinking |
| | | |
During a reboot, the green light will be off and the orange light will be on for 30-45 seconds. When the reboot is complete, both lights will be off for a second, and then the orange light will come on solid and the green light will begin to blink. Wait several seconds before re-establishing a connection with the control.