ITEMIZED PARTS LIST
ITEM | PART NO. | DESCRIPTION | |
NO. | |||
|
| ||
|
|
| |
1 | 23027C | Cover - Electrical | |
2 | 31513C | Control - Cold | |
3 | 31513C | Control - freeze prot. | |
4 | 191550951550 | Fan Motor | |
5 | 31475C | Fan Blade | |
6 | 20282C | Fan Bracket | |
7 | 70018C | Fan Nut | |
8 | 70091C | Washer - Fan Blade | |
9 | 70009C | Screw - Motor Mounting | |
10 | 66305C | Condenser | |
11 | 50189C | Shroud | |
12 | 66202C | Drier | |
13 | 66267C | Heat Exchanger | |
14* | 35807C | Compressor serv Pak (115v) | |
15 | 35801C | Relay | |
16 | 35795C | Overload | |
17 | 30180C | Overload Spring | |
18 | 30181C | Terminal Cover | |
19 | 30182C | Bale Strap | |
20 | 50076C | Sound Dampner | |
21 | 100806740570 | Grommet | |
22 | 19037000 | Clip - Compressor Mtg. | |
23 | 101516143550 | Stud - Compressor Mtg. | |
24 | 66455C | Evaporator Assy | |
25 | 23025C | Panel - Front | |
26 | 70772C | Drain Plug | |
27 | 23033C | Panel - Side Right Hand | |
28 | 23034C | Panel - Side left Hand | |
29 | 23036C | Air Deflector | |
30 | 23037C | Electrical Compartment | |
31 | 23031C | Bracket - Evap. Locating | |
NS | 23026C | Panel - Rear | |
NS | 23028C | Cover - Top | |
|
|
| |
| |||
|
|
| |
ITEM | PART NO. | DESCRIPTION | |
NO. | |||
|
| ||
|
|
| |
4 | 191555551550 | Fan Motor | |
13 | 66476C | Heat Exchanger | |
14* | 35809C | Compressor Serv Pak | |
15 | 35802C | Relay | |
16 | 35796C | Overload | |
|
|
|
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water cooler or orders for repair parts MUST include model number and serial number of cooler, name and part number of replacement part.
INSTALLATION
1.It is important to insure proper ventilation. For remote installation a minimum clearance of 6 inches (152 mm) to the front must be maintained, 1 inch (25 mm) each side, 3 inches (76 mm) to the rear above the unit. Wall grille
2.Water inlet is 1/4" (6 mm) O.D. tube. Contractor to supply connections as required.
3.Connecting lines to be of copper, thoroughly flushed to remove all foreign matter before being connected to cooler. If flushing does not remove all particles, a water strainer should be installed in supply line
4.Connect cooler to building supply line with a
5.Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial plate. Never wire compressor directly to the power supply.
START-UP
1.Open supply line valve.
2.Purge air from all water lines by operating bubbler valve of fountain to which cooler is connected. Steady stream assures all air removed.
3.Rotate fan to insure proper clearance and free fan action.
4.Connect to electrical power.
TROUBLE SHOOTING & MAINTENANCE
Temperature Control: Factory set at 50°F (+/- 5°) under normal conditions. For colder water, adjust screw on item no. 3 CW.
Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with brush, air hose or vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the compressor overload prctector.
Lubrication: Motors are lifetime lubricated.
30
31
24
29
28
FREEZEPROTECT
THERMOSTAT
COLD CONTROL
THERMOSTAT
WIRING DIAGRAM
3 | 2 | 1 |
4 TO 9
10,11
12
13
14
15 TO 19
27
20
25 | 26 | 21 TO 23 |
ELKAY MANUFACTURING COMPANY - 2222 CAMDEN COURT - OAK BROOK, IL 60523 - 630.574.8484
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
96602C (Rev. D)