ERO28C*B ER028RAC*B
| PARTS LIST |
|
|
ITEM NO. PARTNO. | DESCRIPTION |
1A54874 Orifice Assy
2 50934C Housing Assy
3 50168C Pedestal
470012C Bubbler Locknut
5 LK464 Drain
6 15005C Retaining Nut
750986C Regulator Holder
8 61313C Regulator
9 55000604 Fountain
1027623C Fountain
1155000661 Bottom Cover
1255000665 Bottom Cover
1326839C Upper Panel
1426833C Lower Panel
15110711942550 Screw
1655996C Strainer
1740045C Hex Nut
1870055C Speed Nut
1970745C
2022525C Regulator Mounting
2122526C Solenoid Mounting Bracket
2227057C Regulator Mounting
2327240C Sensor Support Mounting Bracket
2431272C Solenoid Valve Assy
2531376C Power Cord
2631384C Sensor Assy
2734783003 Washer - Star #10
2838417001 Screw -
2956082C Nut - Regulator
3070016C Hex Nut
3145662C Push Button
3245663C Push Button Sleeve
3350203C Strain Relief
3451409C Spacer - 1/2 X .44
3570022C Set Screw
3670208C Screw -
3770256C Screw -
3870817C Elbow - 1/4 X 1/4
3970852C Tee - 3/8
4075491C Union - 3/8 Stem X 1/4 Tube
4175507C Fitting - 1/4 NPTF X 1/4 O.D.
42111008343890 Screw -
43111577243890 Screw-
44111577343890 Hex Nut -
4556092C Poly Tubing 48" (Cut To Length)
2NOTE: WHEN INSTALLING REPLACEMENT BUBBLER AND PEDESTAL, TIGHTEN
NUT (ITEM 4) ONLY TO HOLD
13 PARTS SNUG IN POSITION. DO
NOT OVER TIGHTEN.
TROUBLE SHOOTING AND MAINTENANCE
1.Orifice Assy: Minerals deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file not over 1/8" diameter or a small diameter wire. CAUTION: Do not file or cut orifice materials.
2.Stream Regulator: If orifice is free of material deposits regulate water flow according to instructions on page 3.
3.Sensor Control: The sensor has a 2 second delay time. If sensor fails to operate valve mechanism or operates erratically, check the following:
a)Ensure there are no obstructions within a 40 inch radius from the front of fountain.
b)Check wire connections at the solenoid valve and at the sensor. CAUTION: Make sure unit is unplugged before checking any wiring.
c)Ensure proper operation of solenoid valve. If there is an audible clicking sound yet no water flows, look for an obstruction in the valve itself or elsewhere in the water supply line. WARNING: Do not expose sensor to direct sunlight.
4.Sensor Range Adjustment: The electronic sensor used in this fountain is factory
a)Remove bottom cover of fountain.
b)Remove sensor by removing washers and nuts that secure sensor on studs.
c)Locate range adjustment screw between the red lenses of the sensor, then with a small tip screwdriver, rotate the range adjusting screw clockwise to increase range or
CAUTION: Complete range of sensor (24 - 48 inches) is only one turn of the adjusting screw.
d)Remount sensor on studs and replace bottom cover.
45 | 9 |
| |
SEE FIG. 8 | 43, 44 |
45 |
|
10 | 43, 44 |
SEE FIG. 5 |
|
12, 15, 18 | 5 |
FIG. 6 | 11, 15, 18 |
|
|
|
| FIG. 7 | 24 |
|
| 4 |
| |
|
|
|
| |
32 | 17 | 6 | 7 |
|
31 | 8 |
| 28 | |
|
|
ERO28CERO28RAC
35 | FIG. 8 | FIG. 9 |
| ||
| 22 |
|
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
97114C (Rev. F - 01/01) | PAGE 4 |