10. TROUBLESHOOTING HINTS
Symptom | Possible cause/countermeasure |
|
|
No image on the screen | • Cable is not properly connected to the |
| |
| monitor. |
| • The power cord is disconnected from the wall AC outlet. |
| • The plug is disconnected from the power cord receptacle of the |
| Presenter. |
| • The power switch is not turned ON. |
| • Zoom is set at TELE to display only white/black part of the |
| material. |
| • The switch is turned ON immediately after it is turned OFF. In |
| this case, the Presenter may not start. Wait several seconds after |
| turning OFF the power switch, and then turn ON the power |
| switch. |
| • The In/Out selector switch is not correctly selected according to |
| connected equipment (See P. 8 and 13). |
|
|
Out of focus | • The object is too close to the lens. Check if it does not stand |
| higher than 15 cm (5.9 in.) above the stage surface. |
| • Zoom is set at TELE after focusing at WIDE angle. |
| Focus on the point of max. TELE. |
| • In the auto focus, focusing is difficult in some cases. |
|
|
The lamp is not quickly turned ON. | • For protection purposes, the lamp is turned ON after preheating |
| for 2 seconds. This is not a fault. |
|
|
Image is too dark. | • The ambient light is not sufficient. Press the lighting unit button |
| [LAMP] to turn ON the upper lamp. |
|
|
The image of printed matter is striped. | • This is caused by the interference between the dots of printed |
| matter and the scanning line. |
|
|
The image flickers | • The light from the discharge tube (50Hz) does not come to the |
| screen. This may be reduced by setting the [C] key of the In/Out |
| selector switch to [1] (50Hz) (See P. 8). |
|
|
If the trouble still remains after checking the above, consult your dealer or an authorized ELMO service center.
28