Should you wish to construct your own custom power cable, Elo highly recommends using AMP "Mate-N-Lock" part number 350766-1 and male type contacts, AMP part number 350547-1.

After connecting the power cable to the monitor, but before applying power, ensure that the power cable’s black or brown wire connects to the monitor’s brown wire; the power cable’s green wire connects to the monitor’s green wire; and the power cable’s white or blue wire connects to the monitor’s blue wire.

Note: The cable used must include a green (earth ground) wire, it must be 18AWG (or larger), and it should be rated SVT 105C 600V (or better).