EMC 4K VA 20K VA UPS Technical Specifications, For model with 3 Phase in 1 Phase out

Models: 4K VA 20K VA UPS

1 23
Download 23 pages 39 Kb
Page 17
Image 17

9. Technical Specifications

For model with 3 Phase in 1 Phase out

Tower model (with LCD display)

8K31

10K31

12K31

 

15K31

 

20K31

Capacity

Capacity (VA)

8000VA

10000VA

12000VA

 

15000VA

 

20000VA

Capacity (W)

5600W

7000W

8400W

 

10500W

 

14000W

 

 

 

 

 

 

208/360V, 220/380V, 230/400V, 240/415V(3Ф5W)

 

 

 

 

Load Capacity

Voltage/Range

 

Load Capacity

 

Voltage/Load

208~241V

0~25%

 

 

 

 

 

Environment

Shipping Weight kg

151.5 (333.3)

 

206.5 (454.3)

 

246.5 (542.3)

(lb) W/ ISOTR

 

 

 

 

 

 

 

Operating

 

 

0~40°C / 32~104°F

 

Temperature

 

 

 

 

 

 

 

 

Storage

 

-20~50°C / -4~122°F

 

Temperature

 

 

 

 

 

 

 

Altitude

 

 

3,500 meters max

 

Audible Noise (1

 

 

< 55 dB

 

meter from surface)

 

 

 

 

 

 

 

 

 

 

 

 

Relative Humidity

 

0 ~ 95% humidity, non-condensing

 

Input

 

 

 

 

 

 

 

312~478V

 

0~100%

 

242~276V

0~40%

 

 

 

 

 

 

 

 

 

 

 

 

277~311V

0~75%

 

 

 

 

 

 

 

 

Frequency

 

 

 

 

50/60 Hz Auto Sensing

 

 

 

Voltage (on battery)

100V, 110V, 115V, 120V / 208V, 220V, 230V, 240V +/-2% (Selectable Output Voltage)

 

Frequency (on battery)

 

 

 

 

 

50 / 60 Hz +/-0.5%

 

 

 

Transfer Time

 

 

 

 

 

 

0 ms

 

 

 

Overload Recovery

 

 

 

 

Auto transfer to UPS

 

 

Output

High Efficiency mode

 

 

 

 

> 97 %

 

 

 

(AC to AC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UPS Design

 

 

On-Line / Fully digitized microprocessor controlled

 

 

Technology

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Wave Form

 

 

 

 

 

 

Sine wave

 

 

 

Harmonic distortion

 

 

 

< 3% of T.H.D. at linear load

 

 

Crest Factor

 

 

 

 

3 : 1

 

 

 

 

Surge Protection

 

 

 

 

IEC61000-4-5 level 3

 

 

Protection

Overload Protection

125% for 1 minutes and 150% for 10 seconds 130% for 10 seconds and 150% for 1.5

and Filtering

 

 

 

 

seconds (On-battery)

 

 

 

 

 

 

 

 

 

 

Short Circuit Protection

UPS output cut off immediately or input fuse / circuit breaker protection

 

Visual Display (LED

UPS on(green), line-mode(green), battery mode(yellow), bypass(yellow), fault(red)

 

model)

 

 

 

 

 

 

 

 

 

 

 

System

Visual Display (LCD

Input / output voltage, input / output frequency, on-line mode, back up mode, battery

model)

 

 

 

 

 

capacity, load level

 

 

Display/

 

 

 

 

 

 

 

 

 

 

 

Audible Alarm (Battery

 

 

 

 

 

 

Beep every 5 sec

 

 

Warning

 

 

 

 

 

 

 

 

back-up)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UPS Fault

 

 

Continuous beeping sound and LCD display

 

 

Communication

 

 

 

RS-232 Serial Port and USB

 

 

Type

 

 

Sealed, maintenance-free lead acid batteries

 

 

DC Voltage (V) Battery

240V /

 

240V /

 

 

 

240V /

 

240V /

240V /

 

12V7.2AH x

 

 

 

 

12V7.2AH x 20 x

 

12V7.2AH x

12V9AH x 20

 

(Tower )

 

12V9AH x 20

 

 

 

 

20

 

 

 

2SET

 

20 x 2SET

x 2SET

 

 

 

 

 

 

 

 

 

Typical Recharge Time

 

 

 

 

 

 

4 hours

 

 

Battery

to 90% Full

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Management

 

Self-test, adjustable battery transfer points and alarm settings

 

 

 

Battery Protection

 

 

Cut off without draining any current when battery is low

 

 

Cold Start (DC start)

 

 

 

 

 

 

YES

 

 

 

Back Up Time (Tower

 

 

About 4~6 min Full load / 10~15min Half load

 

 

model)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Physical

Input Inlet

 

 

 

 

 

 

Hardwire

 

 

 

Receptacles

 

 

 

 

 

 

Hardwire

 

 

 

Dimensions W x D x H

257 x 690 x 715

 

 

 

342 x 690 x 878

 

342 x 863 x 905

 

mm (inch) W/O ISOTR

(10.1" x 27.2" x 28.1")

 

 

(13.5"x27.2"x34.6")

 

(13.5" x 34.0" x 35.6")

 

 

 

 

 

 

 

 

 

 

 

 

 

Net Weight kg (lb) W/O

80.0 (176.0)

 

 

176.5 (388.3)

 

175.0 (385.0)

 

ISOTR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shipping Weight kg (lb)

101.5 (223.3)

 

 

206.5 (454.3)

 

196.0 (432.3)

 

W/O ISOTR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions W x D x

342 x 690 x 715

 

 

 

342 x 690 x 878

 

342 x 863 x 905

 

H mm (inch) W/

 

 

 

 

 

(13.4" x 27.2" x 28.1")

 

 

(13.5"x27.2"x34.6")

 

(13.5" x 34.0" x 35.6")

 

ISOTR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Net Weight kg (lb)

130.0 (286.0)

 

 

176.5 (388.3)

 

225.0 (495.0)

 

W/ ISOTR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Tower model

Tower model (with LCD display)

VGD-4000

 

VGD5000

 

 

VGD-6000

 

VGD-8000

Capacity

 

 

 

 

 

 

 

 

 

 

Capacity (VA)

4000VA

 

5000VA

 

 

6000VA

 

8000VA

 

Capacity (W)

2800W

 

3500W

 

 

4200W

 

5600W

Output

 

208V, 220V, 230V, 240V +/-2% (Selectable Output Voltage) For 4K / 5K / 6K

 

Voltage (on battery)

100V, 110V, 115V, 120V / 208V, 220V, 230V, 240V +/-2% (Selectable Output Voltage)

 

 

 

 

For 6K / 8K with output isolation transformer

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency (on

 

 

50 / 60 Hz +/-0.5%

 

 

battery)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transfer Time

 

 

 

0 ms

 

 

Overload Recovery

 

 

Auto transfer to UPS

 

 

High Efficiency

> 95 %

 

 

> 97 %

 

mode (AC to AC)

 

 

 

 

 

 

 

 

 

 

 

 

 

UPS Design

 

On-Line / Fully digitized microprocessor controlled

 

 

Technology

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Wave Form

 

 

Sine wave

 

 

Harmonic distortion

 

 

< 3% of T.H.D. at linear load

 

 

Crest Factor

 

 

 

3 : 1

 

 

 

Protection and

Surge Protection

 

 

 

 

 

IEC61000-4-5 level 3

Filtering

 

 

 

 

 

 

 

 

 

 

Overload

125% for 1 minutes and 150% for 10 seconds (On-line) 130% for 10 seconds and 150%

 

 

Protection

 

 

for 1.5 seconds (On-battery)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short Circuit

UPS output cut off immediately or input fuse / circuit breaker protection

 

Protection

 

 

 

 

 

 

 

 

 

 

System/Display

Visual Display

UPS on(green), line-mode(green), battery mode(yellow), bypass(yellow), fault(red)

/Warning

(LED model)

 

 

 

 

 

 

 

 

 

 

Visual Display

Input / output voltage, input / output frequency, on-line mode, back up mode, battery

 

(LCD model)

 

 

capacity, load level

 

 

Audible Alarm

 

 

Beep every 5 sec

 

 

(Battery back-up)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UPS Fault

 

 

Continuous beeping sound and LCD display

 

 

Communication

 

 

RS-232 Serial Port and USB

 

Battery

Type

 

 

Sealed, maintenance-free lead acid batteries

 

 

DC Voltage (V)

120V / 12V7AH

 

120V / 12V9AH

 

 

240V / 12V7.2AH

 

240V / 12V7.2AH

 

Battery (Tower )

x 10

 

x 10

 

 

x 20

 

x 20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical Recharge

 

 

4 hours

 

 

Time to 90% Full

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Management

Self-test, adjustable battery transfer points and alarm settings

 

Battery Protection

Cut off without draining any current when battery is low

 

Cold Start (DC

 

 

 

YES

 

 

start)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Back Up Time

4 min. Full load /

 

5 min. Full load /

 

 

About 4~6 min Full load / 10~15min Half load

 

(Tower model)

10 min. Half load

 

13 min. Half load

 

 

 

 

 

 

 

 

 

 

Physical

Input Inlet

 

 

Hardwire

 

 

Receptacles

IEC C13*8 ; C19*2

 

 

Hardwire

 

Dimensions W x D

257*537*440

 

 

257 x 590 x 570

 

 

257 x 690 x 715

 

x H mm (inch) W/O

 

 

 

(10.1" x 27.2" x

 

(10.1”x21.1”x17.3”)

 

 

(10.1"x23.2"x22.4")

 

 

 

ISOTR

 

 

 

28.1")

 

 

 

 

 

 

 

 

 

28

29

Page 17
Image 17
EMC 4K VA 20K VA UPS installation manual Technical Specifications, For model with 3 Phase in 1 Phase out