6
Hardware Data Sheets
6-11
Storage-System Hardware
DAE Data Sheet The rackmount DAE storage-system dimensions and requirements

are shown in the following figure.

Rackmount DAE Dimensions and Requirements

EMC1831
Depth
63 cm
(24.9 in.)
Width
44.5 cm
(17.5 in.)
Height
15.4 cm
(6.1 in.)
3.5 U
Weight (without
packaging) Deskside 30 Deskside 10 Rackmount
Maximum (max disks, SPs) 144 kg (316 lb) 60 kg (132 lb) 35.4 kg (78 lb)
Power requirements
Voltage rating 100 V ac to 240 V ac -10%+/15%, single phase, 47 Hz to
63 Hz; power supplies are auto ranging
Current draw At 100 v ac input 10-slot: 4.0 A
Power consumption 10-slot: 400 VA
Operating environment
Temperature 10oC to 40oC (50o F to 104o F)
Relative humidity Non-condensing, 20% to 80%
Altitude 40oC to 2,438 m (8,000 ft); 37oC to 3,050 m (10,000 ft)
Heat dissipation (max) 30-slot: 4,233 KJ/hr (4,020 BTU/hr)
10-slot: 1,411 KJ/hr (1,340 BTU/hr)
Air flow Front to back
Service clearances
Front 30.3 cm (1 ft)
Back 60.6 cm (2 ft)