TECHNICAL REPAIR GUIDE
!WARNING
Do not attempt repair of this unit unless you are familiar with the necessary tools, equipment, util- ity connections and potential hazards.
Repair should be performed only by a qualified service provider.
Failure to do so could result in reduced perfor- mance of the unit, serious personal injury or death.
This guide contains service checks to assist service personnel in locating and correcting any malfunction that might occur to render the air cleaner ineffective or inop- erative. The air cleaner has been designed with replace- able components, such as the
All voltage measurements indicated can be made with a high voltage D.C. probe and a general purpose volt ohm meter. For example: Simpson 260 or equivalent.
NOTE: All tests to be performed with the Ozone Reduc- tion Jumper intact.
NOTE: When servicing the power pack components, all wiring must be routed to factory specifications.
120 VAC
Connector | |||
L1 |
| L2 | |
|
|
| Operating |
|
|
| Light |
|
|
| ON/OFF |
| Blk | Wht | Switch |
Wht | Blu | ||
|
|
| Blk |
|
|
| Red |
|
| Gnd |
|
|
|
| Power |
|
|
| Supply |
Power Pack
Assembly
Cover Assembly
Cell Contact
& Insulator
Power Supply
Specifications
The
Input voltage: 120 VAC 50/60 Hz.
Output to light: 1.5 to 2.5 VDC
H.V. Output: 6450 VDC (nom)
Collecting Cell
Specifications
1600 cfm - 1.5 Ma @ 6450 VDC
Figure 23