INSTALLATION

REMOVE OLD FILTER AND DISCARD

(Figure 12)

NOTE: This filter may be mounted in the furnace compart- ment.

CLEAN BLOWER COMPARTMENT

It is suggested that the furnace blower compartment, blower and blower housing be cleaned to ensure clean air circulation.

INSTALLATION

The following is a typical installation of the air cleaner on a “Highboy” furnace (Figure 8).

1. Place the air filter cleaner on the floor. Stand it upright

with the power door facing you (Figure 4). If a horizon-

tal installation is being planned, lay the cleaner on its

side, this will help you to visualize the relative location

of all parts.

Allow ample space for wiring and servicing the power

supply box (Figure 13).

2. Release the latch, remove the power pack (by grasp-

ing handle and pulling power pack away from cabi-

net) and set it aside. Remove the collecting cells and

pre-filters. Set pre-filters and cells aside in a safe

location until the cabinet is installed.

3. Set the cabinet next to the furnace. If necessary,

enlarge the opening in the furnace (if possible) to

match the opening in the cabinet.

If the furnace opening cannot be enlarged, a transi-

tion fitting should be used. (Figure 3).

The cabinet can be attached directly (Figure 13), or a

starting collar can first be fitted to the furnace inlet. A

butt or slip joint can be used.

Figure 12

Power

Frame Supply

Box

Duct

Mounting

Holes

Figure 13

Air Flow

Turning

 

Vanes

Securely attach the cabinet to furnace inlet, using at

least two of the mounting holes on each side of the

cabinet.

4. Using butt joint, attach duct work (normally an elbow)

to the upstream side of air cleaner cabinet. (Note the

use of the sheet metal turning vanes inside the elbow

to improve air distribution over the face of the cells.)

(Figure 14)

NOTE: An optional method of attaching duct work to the cabinet is to modify the cabinet (Figure 15) by bending the tabs outward at a 90° angle and attaching duct work to

Optional method

(Bend tabs outward at 90°angle)

Figure 14

Figure 15

tabs.

Transition Fittings

If the air duct does not fit the cabinet opening, a transition fitting should be used. Gradual transitions are preferred for greatest efficiency. Not more than four inches per linear foot (approximately 20° angle) should be allowed (Figure 3).

5.Connect the vertical duct section to the elbow. Wedge a wood block between floor and elbow for support (Figure 16).

6.Seal all joints in the return air system downstream from the air cleaner with duct tape to prevent dust from entering the air stream. Tape is usually applied on the outside of ducts, but may also be applied on the inside, or both.

6

Page 6
Image 6
Emerson 16C26S-010 owner manual Remove OLD Filter and Discard Clean Blower Compartment, Installation, Transition Fittings

16C26S-010 specifications

The Emerson 16C26S-010 is a versatile and innovative control solution that has been designed to meet the rigorous demands of various industrial applications. As part of Emerson's extensive offerings, this device serves as a powerful tool for automation and process control, providing enhance functionality and seamless integration with existing systems.

One of the main features of the Emerson 16C26S-010 is its advanced control algorithms. These algorithms enable the device to achieve precise and stable control of processes, ensuring optimal performance. The built-in PID control capability further enhances its effectiveness, allowing users to customize control parameters to suit their specific requirements. This adaptability makes the 16C26S-010 an ideal choice for a variety of applications, including temperature regulation, flow control, and pressure management.

Another notable characteristic of the Emerson 16C26S-010 is its user-friendly design. The device comes equipped with an intuitive interface and easy-to-navigate menus that simplify the setup process. This interface allows users to quickly program and adjust settings, facilitating faster response times and reduced downtime. Additionally, the robust construction of the unit ensures durability and reliability in demanding environments, making it suitable for both indoor and outdoor use.

Connectivity is a key feature of the Emerson 16C26S-010. The device supports various communication protocols, including Modbus and Ethernet, enabling seamless integration with other devices and systems. This connectivity allows for real-time monitoring and control, fostering improved decision-making and operational efficiency.

Moreover, the Emerson 16C26S-010 is designed with energy efficiency in mind. Its intelligent control strategies help minimize energy consumption, leading to cost savings and a reduced environmental footprint. This focus on sustainability aligns with modern industry trends that prioritize environmentally responsible practices.

In summary, the Emerson 16C26S-010 stands out as an exceptional control solution characterized by its advanced algorithms, user-friendly interface, robust construction, extensive connectivity options, and energy efficiency. These features make it a valuable asset for any industrial automation application, ensuring reliability and performance while meeting the evolving needs of the market.