WIRING INSTRUCTIONS

WIRING INSTRUCTIONS

7.With the cabinet installed, the air cleaner can now be wired to electrical input source.

!WARNING

Installation of this unit must comply with local electric codes or other applicable codes.

Review and understand local codes prior to in- stallation.

Failure to do so could result in serious personal injury or death.

8.

The air cleaner must be wired through the furnace

 

controls. This unit requires a 120 VAC 60 Hz input

 

circuit. A 20 amp circuit is more than adequate.

9.

Remove junction box cover and install the required

 

bushing into the 3/4 in. knock out. With the supply

 

voltage turned off, route three (3) wires into junction

 

box for connections. (See Fig. 17.)

 

Insure all wires are clamped, wire connectors prop-

 

erly installed and grommets used to prevent wire

 

abrasion.

10.

The air cleaner must be wired to have power supplied

 

when the furnace blower is on and there is airflow

 

through the duct. Some furnace control modules

your system is not equipped with an EAC output terminal, Figure 19 shows a method for installing a relay (customer supplied) to switch power to the air cleaner when the blower is on.

Floor

Conduit

Duct

Electronic

Air Cleaner

Figure 18

Cooling Fan

have an output terminal for an electronic air cleaner

that will energize the unit when the blower is on. If

Relay

(External)

Electronic

Air Cleaner

N.C.

Hi

Vertical

Section

Tape All

Joints

N.O.

N.C.

Black

 

Brown Manual background 120 Volt

60 Hz

N.O.

Fan Control (Open)

N.O.

120 Volt

 

2 Speed

C

N.C.

Fan

 

 

Lo

N.O.

 

 

 

120 Volt

120 Volt

 

Relay (OFF)

 

60 Hz

 

(Customer

 

 

 

Supplied)

 

Cooling Mode - Fan Operating in Hi Speed

Cooling Fan

Wood Block

Relay

(External)

Electronic

Figure 16

Air Cleaner

N.C.

Hi

Hot

Hot

N.O.

Black

N.C.

 

Brown

N.O.

120 Volt

 

2 Speed

C

N.C.

Fan

 

 

Lo

 

Grounding

Conductor

Front View

N.O.

120 Volt

60 Hz

Fan Control (Closed)

N.O.

 

120 Volt

120 Volt

Relay (ON)

60 Hz

(Customer

 

Supplied)

 

Figure 17

Heating Mode - Fan Operating in Low Speed

Figure 19

7

Page 7
Image 7
Emerson 16C26S-010 owner manual Wiring Instructions