![Save these instructions for future use!](/images/new-backgrounds/45274/452741x1.webp)
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.
Big Blue Touchscreen Thermostat with Automatic Heat/Cool Changeover Option
Installation and Operating Instructions for Model:
Model | Programming Choices | ||
|
|
| |
5+1+1 Day | 7 Day | ||
|
|
|
|
APPLICATIONS
THERMOSTAT APPLICATION GUIDE |
| |
|
| |
Description |
|
|
Heat Pump (No Aux.. or Emergency Heat) | Yes |
|
Heat Pump (with Aux.. or Emergency Heat) | Yes |
|
Systems with up to 3 Stages Heat, 2 Stages Cool | No |
|
Heat Only Systems | Yes |
|
Millivolt Heat Only Systems – Floor or Wall Furnaces | Yes |
|
Cool Only Systems | Yes |
|
Gas or Oil Heat | Yes |
|
Electric Furnace | Yes |
|
Hydronic (Hot Water) Zone Heat – 2 Wires | Yes |
|
Hydronic (Hot Water) Zone Heat – 3 Wires | Yes |
|
Wired Remote Temperature Sensor (Indoor/Outdoor) | Yes |
|
Dual Fuel Feature (Heat Pump Mode) | Yes |
|
|
|
| SPECIFICATIONS |
Electrical Rating: |
|
| |
|
|
| |
Battery Power | . . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC | ||
. . . . . . . . . . . . . . . 20. . to. 30 VAC | |||
Terminal Load | . . . . . . . . . . . . . . 1. ...5A. | .per. . terminal, 2..5A maximum all terminals combined | |
Setpoint Range | . . . . . . . . . . . . . . . .45. .to. 99°F (7 to 37°C) | ||
Differential (Single Stage) . . . | . . . . . . . . . . . . . . . . Heat. | 0..6°F; Cool 1..2°F | |
Differential | . . . . . . . . . . . . . . . Heat. . . 0..6°F; Cool 1..2°F | ||
Differential (Heat Pump) . . . | . . . . . . . . . . . . . .Heat. . . 1...2°F; Cool 1..5°F | ||
Operating Ambient | . . . . . . . . . . . . . . . . . 32°F to +105°F (0 to +41°C) | ||
Operating Humidity | . . . . . . . . . . . . . . . 90%. . . | ||
Shipping Temperature Range | . . . . . . . . . . . . . . . | ||
Dimensions Thermostat | . . . . . . . . . . . . . . . . . | ||
|
|
|
|
!CAUTION
To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
Index | Page |
Installation | 2 |
Wiring Connections | 2 |
Thermostat Quick Reference | 4 |
Installer Configuration Menu | 5 |
Operating Your Thermostat | 8 |
Programming | 9 |
Troubleshooting | 12 |
ATTENTION: MERCURY NOTICE
This product does not contain mercury. . However, this product may replace a product that contains mercury..
Mercury and products containing mercury must not be discarded in household trash. . Do not touch any spilled mercury. . Wearing
| PART NO. |
| |
www.emersonclimate.com | 1241 |