Emerson 1F97-1277 specifications Applications, Save these instructions for future use, Index

Models: 1F97-1277

1 12
Download 12 pages 56.04 Kb
Page 1
Image 1
Save these instructions for future use!

Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

Big Blue Touchscreen Thermostat with Automatic Heat/Cool Changeover Option

Installation and Operating Instructions for Model:

Model

Programming Choices

 

 

 

1F97-1277

Non-Programmable

5+1+1 Day

7 Day

 

 

 

 

APPLICATIONS

THERMOSTAT APPLICATION GUIDE

 

1F97-1277 Touchscreen Thermostat

 

 

Description

 

 

Heat Pump (No Aux.. or Emergency Heat)

Yes

 

Heat Pump (with Aux.. or Emergency Heat)

Yes

 

Systems with up to 3 Stages Heat, 2 Stages Cool

No

 

Heat Only Systems

Yes

 

Millivolt Heat Only Systems – Floor or Wall Furnaces

Yes

 

Cool Only Systems

Yes

 

Gas or Oil Heat

Yes

 

Electric Furnace

Yes

 

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

 

Hydronic (Hot Water) Zone Heat – 3 Wires

Yes

 

Wired Remote Temperature Sensor (Indoor/Outdoor)

Yes

 

Dual Fuel Feature (Heat Pump Mode)

Yes

 

 

 

 

SPECIFICATIONS

Electrical Rating:

 

 

 

 

 

Battery Power

. . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC

Input-Hardwire

. . . . . . . . . . . . . . . 20. . to. 30 VAC

Terminal Load

. . . . . . . . . . . . . . 1. ...5A.

.per. . terminal, 2..5A maximum all terminals combined

Setpoint Range

. . . . . . . . . . . . . . . .45. .to. 99°F (7 to 37°C)

Differential (Single Stage) . . .

. . . . . . . . . . . . . . . . Heat.

0..6°F; Cool 1..2°F

Differential (Multi-Stage) . . .

. . . . . . . . . . . . . . . Heat. . . 0..6°F; Cool 1..2°F

Differential (Heat Pump) . . .

. . . . . . . . . . . . . .Heat. . . 1...2°F; Cool 1..5°F

Operating Ambient

. . . . . . . . . . . . . . . . . 32°F to +105°F (0 to +41°C)

Operating Humidity

. . . . . . . . . . . . . . . 90%. . . non-condensing max..

Shipping Temperature Range

. . . . . . . . . . . . . . . -4. .to +150°F (-20 to +65°C)

Dimensions Thermostat

. . . . . . . . . . . . . . . . . 4-9/16"H x 5-13/16"W x 1-3/16"D

 

 

 

 

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

Index

Page

Installation

2

Wiring Connections

2

Thermostat Quick Reference

4

Installer Configuration Menu

5

Operating Your Thermostat

8

Programming

9

Troubleshooting

12

ATTENTION: MERCURY NOTICE

This product does not contain mercury. . However, this product may replace a product that contains mercury..

Mercury and products containing mercury must not be discarded in household trash. . Do not touch any spilled mercury. . Wearing non-absorbent gloves, clean up any spilled mercury and place in a sealed container.. For proper disposal of a product containing mercury or a sealed container of spilled mercury, place it in a suitable shipping container. . Refer to www.thermostat-recycle.orgfor location to send the product containing mercury..

 

PART NO. 37-7388A

www.white-rodgers.com

 

www.emersonclimate.com

1241

Page 1