Emerson 3350 g.Position gland clamping insert so the interior end is flush with the heat shrink

Models: 3350 3700

1 24
Download 24 pages 13.9 Kb
Page 17
Image 17
g.Position gland clamping insert so the interior end is flush with the heat shrink.

Shielded heat shrink completely covers exposed drain wires

g.Position gland clamping insert so the interior end is flush with the heat shrink.

h.Fold the cloth shield or braid and drain wires over the clamping insert and approximately 1/8 inch (3 mm) past the O-ring.

i.Install the gland body into the core processor housing conduit opening.

5.Insert the wires through the gland body and assemble the gland by tightening the gland nut.

6.Identify the wires in the 4-wire cable. The 4-wire cable supplied by Micro Motion consists of one pair of 18 AWG (0,75 mm2) wires (red and black), which should be used for the VDC connection, and one pair of 22 AWG (0,35 mm2) wire (green and white), which should be used for the RS-485 connection. Connect the four wires to the numbered slots on the core processor.

16

Page 17
Image 17
Emerson 3350, 3700 g.Position gland clamping insert so the interior end is flush with the heat shrink