Emerson 396VP, 398VP, 397 Essential Instructions, Hazardous Area Installation

Models: 398 397 396VP 398VP 396

1 40
Download 40 pages 16.63 Kb
Page 2
Image 2

ESSENTIAL INSTRUCTIONS

READ THIS PAGE BEFORE PROCEEDING!

Rosemount Analytical designs, manufactures, and tests its products to meet many national and international standards. Because these instruments are sophisticated technical products, you must properly install, use, and main- tain them to ensure they continue to operate within their normal specifica- tions. The following instructions must be adhered to and integrated into your safety program when installing, using, and maintaining Rosemount Analytical products. Failure to follow the proper instructions may cause any one of the following situations to occur: Loss of life; personal injury; proper- ty damage; damage to this instrument; and warranty invalidation.

Read all instructions prior to installing, operating, and servicing the prod- uct. If this Instruction Manual is not the correct manual, telephone 1-800- 654-7768 and the requested manual will be provided. Save this Instruction Manual for future reference.

If you do not understand any of the instructions, contact your Rosemount representative for clarification.

Follow all warnings, cautions, and instructions marked on and supplied with the product.

Inform and educate your personnel in the proper installation, operation, and maintenance of the product.

Install your equipment as specified in the Installation Instructions of the appropriate Instruction Manual and per applicable local and national codes. Connect all products to the proper electrical and pressure sources.

To ensure proper performance, use qualified personnel to install, operate, update, program, and maintain the product.

When replacement parts are required, ensure that qualified people use replacement parts specified by Rosemount. Unauthorized parts and pro- cedures can affect the product’s performance and place the safe opera- tion of your process at risk. Look alike substitutions may result in fire, electrical hazards, or improper operation.

DANGER

HAZARDOUS AREA INSTALLATION

This sensor is not Intrinsically Safe. or Explosion Proof. Installations near flammable liquids or in hazardous area locations must be carefully evaluated by qualified on site safety personnel.

To secure and maintain an intrinsically safe installation, an appropriate transmitter/safety barrier/sensor combination must be used. The installation system must be in accordance with the governing approval agency (FM, CSA or BASEEFA/CENELEC) hazardous area classifi- cation requirements. Consult your analyzer/ transmitter instruction manual for details.

Proper installation, operation and servicing of this sensor in a Hazardous Area Installation is entirely the responsibility of the user.

CAUTION

SENSOR/PROCESS

APPLICATION COMPATIBILITY

The wetted sensor materials may not be com- patible with process composition and operat- ing conditions. Application compatibility is entirely the responsibility of the user.

About This Document

This manual contains instructions for installation and operation of the Models 396, 396VP, 397, 398, and 398VP TUpH pH/ORP Sensors. The following list provides notes concerning all revisions of this document.

Rev. Level

Date

Notes

03/99 This is the initial release of the product manual. The manual has been reformatted to reflect the Emerson documentation style and updated to reflect any changes in the product offering.

A12/01 Revised wiring diagram on page 24.

B2/02 Added patent info to page 1.

C6/02 Updated multiple drawings.

D8/02 Added drawing #40105549, rev. D.

E10/02 Revised drawing #40039601, rev. J, on page 10.

F4/03 Revised Model 397 specs on page 2, and revised drawing on page 27.

G8/03 Added Silcore information.

H3/04 Added Xmt wiring drawings.

I10/04 Added 5081 wiring drawing and updated 1055 wiring.

J2/06 Changed drawing 40039603 rev. C, on page 13. Added a note on page 15.

Emerson Process Management

Liquid Division

2400 Barranca Parkway

Irvine, CA 92606 USA

Tel: (949) 757-8500

Fax: (949) 474-7250

http://www.raihome.com

© Rosemount Analytical Inc. 2006

Page 2
Image 2
Emerson 396VP, 398VP, 397 instruction manual Essential Instructions, Hazardous Area Installation

398, 397, 396VP, 398VP, 396 specifications

Emerson offers a wide range of advanced process control instruments, and among them, the Emerson 396, 398VP, 396VP, 397, and 398 stand out for their precision, reliability, and versatility. These models are designed to cater to the demanding needs of industrial applications, particularly in the areas of pressure, temperature, and flow measurement.

The Emerson 396 series focuses on providing robust pressure and temperature measurement solutions. One of its standout features is its digital manometer functionality, which allows for precise measurement of differential pressure. This makes it an excellent choice for HVAC applications and other industrial processes where accuracy is critical. The 396 model is equipped with advanced signal processing capabilities, allowing for the adjustment of sensitivities and ranges according to specific application needs.

Moving on to the 398VP and 396VP models, these variants incorporate advanced validation features that ensure data integrity and accuracy. They are designed with user-friendly interfaces that not only simplify operation but also enhance user experience. The 398VP model, in particular, is celebrated for its versatility, as it can operate in both electrical and pneumatic environments. Additionally, the model comes with integrated diagnostics, which simplifies maintenance by providing real-time data on operational status.

The Emerson 397 model focuses on flow measurement and control. It integrates technologies that minimize the impact of environmental factors on measurement accuracy. Its intelligent algorithms provide compensation for temperature and pressure fluctuations, ensuring consistent performance in varying conditions. This model is also compatible with various fieldbus protocols, facilitating easy integration into existing systems.

Finally, the Emerson 398 model is known for its high-performance digital operation. It includes features such as remote monitoring and control capabilities, which allow operators to manage processes from any location. The 398 is specifically designed to meet the rigorous requirements of industries like oil and gas, chemical, and power generation.

In summary, the Emerson 396, 398VP, 396VP, 397, and 398 models are equipped with cutting-edge technologies and features tailored for industrial efficiency, reliability, and accuracy. Their user-friendly interfaces, advanced diagnostics, and compatibility with modern communication protocols make them invaluable tools for engineers and operators in various sectors, enhancing overall productivity and performance.