Emerson 397, 396VP, 398VP instruction manual 398 10 32

Models: 398 397 396VP 398VP 396

1 40
Download 40 pages 16.63 Kb
Page 9
Image 9

MODEL 396/396VP/397/398/398VP

SECTION 1.0

 

DESCRIPTION AND SPECIFICATIONS

The Model 398 Sensor, housed in a titanium tube and made with a patented Tefzel ref- erence junction, can be used with a 1 inch MNPT process connector (purchased sepa- rately). The sensor is available with a hemi bulb glass pH electrode or a platinum and glass ORP electrode and with Pt100 or 3K temperature compensation. The 398 is pro- vided with a standard 15 ft cable. A preamplifier must be used if the sensor is more than 15 ft from the analyzer/transmitter. Junction box kits with preamplifiers must be ordered separately. Process connector must also be ordered separately.

MODEL

398 TUpH INSERTION/SUBMERSION TITANIUM pH SENSOR

CODE

MEASURING ELECTRODE TYPE (Required Selection)

10GPHT hemi glass, General Purpose High Temperature (0-14 pH)

12ORP

CODE

 

O-RING MATERIAL (Required Selection)

30

 

EPDM

 

 

 

 

 

31

 

Viton

 

 

 

 

32

 

Kalrez (recommended for applications with Chlorine Dioxide)

 

 

 

 

 

 

 

CODE

 

ANALYZER/TC COMPATIBILITY (Required Selection)

50

 

For Models 1181 (3K TC) [no T.C. if ordered with option -12 (ORP)]

 

 

 

54

 

For Models 54/e, 1054A/B, 1055, 2700, 81, 2081, 3081, 4081, SCL-P, and Solu Cube (Pt-100 RTD)

 

 

 

CODE

 

OPTIONAL SELECTIONS (see drawings on page 4)

 

 

 

62

 

No BNC (Not Valid w/Option 50) for wiring directly to 54/e, 1055, 81, 3081, and 4081 Transmitter/Analyzers

 

 

 

 

398

- 10 - 32 - 54

EXAMPLE

 

 

 

 

The Model 398VP insertion/submersion sensor is the same as Model 398, except the cable is replaced with a Variopol connector. The watertight Variopol sensor-to- cable connector uses the mating connector cable (ordered separately).

MODEL

 

398VP

TUpH INSERTION/SUBMERSION TITANIUM AND TEFZEL pH/ORP SENSOR

 

 

CODE

MEASURING ELECTRODE TYPE (Required Selection)

10

GPHT hemi glass, General Purpose High Temperature (0-14 pH)

12ORP

13Flat

CODE

O-RING MATERIAL (Required Selection)

30EPDM

31Viton

32Kalrez (recommended for applications with Chlorine Dioxide)

CODE

ANALYZER/TC COMPATIBILITY (Required Selection)

50

For Models 1181

(3K TC) [no T.C. if ordered with option -12 (ORP)]

 

 

54

For Models 54/e, 1054A/B, 1055, 2700, 81, 2081, 3081, 4081, SCL-P, and Solu Cube (Pt-100 RTD)

 

 

 

 

398VP -

10 - 32 -

54

EXAMPLE

 

 

 

 

5