MODEL 396/396VP/397/398/398VP

SECTION 1.0

 

DESCRIPTION AND SPECIFICATIONS

The TUpH Model 397 pH Sensor is housed in a polypropylene body and is designed to be used with the Quik-Loc Kit. The sensor includes a large general purpose (GPHT) glass pH electrode and a large area polypropylene reference junction with gel filled reference electrolyte. The Model 397 is available without an integral preamplifier only and 15 ft (4.6 m) of cable.

 

MODEL

 

 

397

TUpH pH SENSOR

 

 

 

 

 

CODE

PREAMPLIFIER/CABLE (Required Selection)

02

Without integral preamplifier, 15 ft (4.6 m) cable

 

 

 

 

 

 

 

 

 

CODE

MEASURING ELECTRODE TYPE (Required Selection)

10

GPHT, General Purpose glass (0-14 pH)

 

 

 

 

 

 

 

 

 

CODE

ANALYZER/TC COMPATIBILITY (Required Selection)

50

For Models 1181, 1050, 1003 (3 K Balco TC)

 

 

 

 

54

For Models 1054, 1055, 54e, 81, 3081, 4081, 2081; 2700-Code 02 only (PT-100 RTD)

 

 

 

 

 

 

 

 

CODE

OPTIONAL OPTIONS

 

62

Cable without BNC for wiring to 54/e, 1055, 81, 3081, 4081 analyzers

 

 

 

 

FOR FIRST TIME 397/QUIK-LOC INSTALLATIONS, USING THE FOLLOWING GUIDE IS RECOMMENDED:

1. Quik-Loc Mounting (required for all first time installations)

Choose one: PN 23757-00, Quik-Loc Kit: for use in 1 in. tees; insertion depth 1.4 in. (35 mm)

PN 23757-01, Quik-Loc Kit: for use in 1-1/2 in. and 2 in. tees; insertion depth 2 in. (50 mm)

2.Remote Junction Boxes (optional, recommended for sensor to analyzer distances of more than 15 ft) Choose one: PN 23555-00 includes preamplifier for Models 54, 81, 3081, 4081

PN 23309-03 and PN 22698-02 plug-in preamplifier for Model 1181Analyzer

PN 23309-04 and PN 22698-03 plug-in preamplifier for Models 1054 series, 2054, and 2081 Analyzers PN 23054-03 includes preamplifier for Solu Cube Model 2700

3.Extension cables (used with remote junction boxes)

Choose one: PN 23646-01, 11 conductor, shielded, prepped

PN 9200273, 11 conductor, shielded, unprepped

4. Wiring Aids

Choose one: PN 9120531 BNC splitter, used in place of option -62 or BNC coax prepping for connections to junction box (PN 23555-00); Models 1181, 1054, 2081, 54, 81, 3081, 4081; Solu Comp (SCL-P-014); and Model 2700 Preamplifier (PN 23054-03)

NONE: No wiring aids required for connections to Models 1054A, 1054B, 2054, or preamplifiers

PN 22698-02 or 22698-03

6

Page 10
Image 10
Emerson 396VP, 398VP, 397 instruction manual Model

398, 397, 396VP, 398VP, 396 specifications

Emerson offers a wide range of advanced process control instruments, and among them, the Emerson 396, 398VP, 396VP, 397, and 398 stand out for their precision, reliability, and versatility. These models are designed to cater to the demanding needs of industrial applications, particularly in the areas of pressure, temperature, and flow measurement.

The Emerson 396 series focuses on providing robust pressure and temperature measurement solutions. One of its standout features is its digital manometer functionality, which allows for precise measurement of differential pressure. This makes it an excellent choice for HVAC applications and other industrial processes where accuracy is critical. The 396 model is equipped with advanced signal processing capabilities, allowing for the adjustment of sensitivities and ranges according to specific application needs.

Moving on to the 398VP and 396VP models, these variants incorporate advanced validation features that ensure data integrity and accuracy. They are designed with user-friendly interfaces that not only simplify operation but also enhance user experience. The 398VP model, in particular, is celebrated for its versatility, as it can operate in both electrical and pneumatic environments. Additionally, the model comes with integrated diagnostics, which simplifies maintenance by providing real-time data on operational status.

The Emerson 397 model focuses on flow measurement and control. It integrates technologies that minimize the impact of environmental factors on measurement accuracy. Its intelligent algorithms provide compensation for temperature and pressure fluctuations, ensuring consistent performance in varying conditions. This model is also compatible with various fieldbus protocols, facilitating easy integration into existing systems.

Finally, the Emerson 398 model is known for its high-performance digital operation. It includes features such as remote monitoring and control capabilities, which allow operators to manage processes from any location. The 398 is specifically designed to meet the rigorous requirements of industries like oil and gas, chemical, and power generation.

In summary, the Emerson 396, 398VP, 396VP, 397, and 398 models are equipped with cutting-edge technologies and features tailored for industrial efficiency, reliability, and accuracy. Their user-friendly interfaces, advanced diagnostics, and compatibility with modern communication protocols make them invaluable tools for engineers and operators in various sectors, enhancing overall productivity and performance.