Monitor: Monitor Recovery and Updates
10006024-04 Katana®752i User’s Manual 15-7

MONITOR RECOVERY AND UPDATES

Note: The monitor provides VxWorks 6.0 support for Error Data and Reporting (EDNR). This feature allocates a per-
sistent area of memory that retains its contents after a systerm soft reset. Any information stored in the 32-
megabyte window starting at 0x1E000000 should stil be available after a soft resset.
This section describes how to recover and/or update the monitor, given one or more of the
following conditions:
If there is no console output, the monitor may be corrupted and need recovering.
If the monitor still functions, but is not operating properly, then you may need to reset
the environment variables.

Recovering the Monitor

First, make sure that a monitor ROM device is installed in the PLCC socket. Then, place a
jumper on JP2, across pins 1 and 2 (see Fig.2-4).
1Issue the following command, where serial# is the four digit serial number, 683-xxxx:
[Katana 752i (1.0)] => moninit serial#
2Reset the monitor:
[Katana 752i (1.0)] => reset
3Reset the environment parameters:
[Katana 752i (1.0)] => envinit serial#
4Power down the board and remove the jumper from JP2, pins 1 and 2.

Updating the Monitor via TFTP

To update the monitor, follow the steps below and insert the appropriate data in the itali-
cized fields.
1If necessary, edit your network settings:
[Katana 752i (1.0)] => setenv ipaddr 192.168.1.100
[Katana 752i (1.0)] => setenv gatewayip 192.168.1.1
[Katana 752i (1.0)] => setenv netmask 255.255.255.0
[Katana 752i (1.0)] => setenv serverip 192.168.1.2
Optionally, save your settings:
[Katana 752i (1.0)] => saveenv
2TFTP the new monitor (binary) image to memory location 0x100000:
[Katana 752i (1.0)] =>
tftpboot 100000 path/on/tftp/server/to/monitor.bin