14.Reinstall the hanger ball (Figure 12) on the downrod as follows. Route the three 80” motor leads through the hanger ball. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.

!WARNING

It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.

15.The fan comes with black and white leads that are 80-inches long. Before installing the fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.

16.You have now completed the assembly of your new ceiling fan. You can now proceed with hanging and wiring your fan.

HANGER

PIN

 

BALL

 

CEILING

DOWNROD

COVER

 

SETSCREW

 

Figure 12

 

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

CAUTION: To reduce the risk of electrical shock, disconnect the electrical supply circuit before installing the fan, light kit or receiver.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support of 15.9kg. (35 lbs.) or less”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

!WARNING

To avoid fire or shock, follow all wiring instructions carefully.

Any electrical work not described in these instructions should be done or approved by a licensed electrician.

 

emersonfans.com

7

Please contact 1-800-654-3545 for further assistance

ETL Model No.: CF110

Page 7
Image 7
Emerson CF110ORB00, CF110BS00 owner manual Electrical Requirements

CF110ORB00, CF110BS00 specifications

The Emerson CF110BS00 and CF110ORB00 are two striking ceiling fan models that seamlessly blend aesthetics with functionality, making them perfect additions to various interior designs. These fans are crafted to cater to homeowners looking to enhance their living spaces while ensuring optimal air circulation and energy efficiency.

One of the most notable features of the Emerson CF110BS00 and CF110ORB00 is their sleek and stylish design. Available in two distinct finishes — brushed steel (BS) and oil-rubbed bronze (ORB) — these fans can complement a wide range of decor styles, from modern minimalist to rustic charm. The subtle elegance of the finishes allows them to act as both functional appliances and decorative elements in any room.

These fans are equipped with a robust motor that ensures powerful airflow. The high-performance motor design becomes especially beneficial during the hot summer months, delivering a refreshing breeze while reducing the reliance on air conditioning units, which can lead to significant energy savings. The CF110BS00 and CF110ORB00 also feature three speed settings, allowing users to customize airflow according to their comfort levels.

Another essential characteristic of these ceiling fans is their versatility. They come with a reversible function, enabling them to operate in both clockwise and counterclockwise directions. This feature not only aids in cooling during warmer seasons but also assists in circulating warm air during colder months, making these fans a year-round solution for climate control.

The Emerson CF110BS00 and CF110ORB00 also boast easy installation, thanks to their user-friendly design. The integrated light fixture option allows homeowners to enhance their lighting solutions by combining functionality with style. Additionally, compatibility with various control systems, including pull chains and remote controls, ensures convenience in operation.

Safety and energy efficiency are paramount in the design of these ceiling fans. They are crafted from high-quality materials, ensuring durability and longevity. With the added benefit of energy-efficient operation, these fans are designed to minimize utility bills while maintaining comfort.

In summary, the Emerson CF110BS00 and CF110ORB00 ceiling fans are exemplary models that fuse design, performance, and efficiency. With their stylish finishes, powerful motors, versatile operation, and easy installation, they represent an ideal choice for anyone looking to elevate their home's comfort and aesthetic.