Emerson CF200n100 owner manual Trouble Shooting, Probable Cause, Suggested Remedy

Models: CF200n100

1 16
Download 16 pages 51.14 Kb
Page 14
Image 14
Trouble Shooting

BP7354 CF200 9/19/07 11:30 AM Page 14

!WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.

Trouble Shooting

TROUBLE

PROBABLE CAUSE

 

SUGGESTED REMEDY

 

 

 

 

1. Fan will not

1. Fuse or circuit breaker

1.

Check main and branch

start.

blown.

 

circuit fuses or circuit breakers.

 

2. Loose power line

2.

Check line power connections

 

connections to the fan, or

 

to fan and wire.

 

loose wire connections in

 

 

 

the switch housing.

 

 

 

3. Wall switch is off.

3.

Turn on wall switch.

 

4. Defective battery in remote

4.

Check that the battery is good

 

control transmitter.

 

(red indicator light should

 

 

 

illuminate when any button is

 

 

 

pressed).

 

5. Code switches in remote

5.

Check that both code switches

 

control receiver and transmitter

 

are set in the same positions.

 

are not set in the same position.

 

WARNING: Make sure

 

 

!

 

 

 

main power is turned off.

2. Fan sounds

1. Blades not attached to fan.

1.

Attach blades to fan before

noisy.

 

 

operating.

 

2. Screws securing fan blade

2.

Check to make sure the screws

 

flanges to motor are loose.

 

which attach the blade flanges

 

 

 

to the motor are tight.

 

3. Wire connectors inside switch

3.

Check to make sure wire

 

housing rattling.

 

connectors in switch housing

 

 

 

are not rattling against each

 

 

 

other or against the interior wall

 

 

 

of the switch housing.

 

 

!

WARNING: Make sure main

 

 

 

power is turned off.

 

4. Screws holding blades to

4.

Tighten screws securely.

 

flanges are loose.

 

 

 

5. Loose screws in motor housing.

5.

Check to make sure all screws

 

 

 

in motor housing are snug

 

 

 

(not over-tight)

 

 

 

 

3. Fan wobbles

1. Setscrew in motor coupling is

1.

Raise coupling cover and tighten

excessively.

not tightened securely.

 

setscrew securely.

 

2. Setscrew in the hanger ball/

2.

Tighten the setscrew in the

 

downrod assembly is loose.

 

hanger ball/downrod assembly.

 

3. Screws securing fan blade

3.

Check to be sure screws which

 

flanges to motor are loose.

 

attach the fan blade flanges

 

 

 

to the motor are tight.

 

4. Fan blade flanges not seated

4.

Check to be sure that the

 

properly.

 

screws securing the fan

 

 

 

blade flanges seat firmly.

 

5. Hanger bracket and/or ceiling

5.

Tighten the hanger bracket

 

outlet box is not securely

 

screws to the outlet box, and/or

 

fastened.

 

secure outlet box.

 

6. Fan blades out of balance.

6.

Interchanging an adjacent (side

 

 

 

by-side) blade pair can

 

 

 

redistribute the weight and result

 

 

 

in smoother operation.

 

 

 

Or use supplied balancing kit to

 

 

 

balance blades.

14

U.L. Model No.: CF200

Page 14
Image 14
Emerson CF200n100 owner manual Trouble Shooting, Probable Cause, Suggested Remedy