BP7408 44" & 52" Curva 1/12/10 8:52 AM Page 10

HANGER BRACKET

HANGER BRACKET GROUND WIRE (GREEN)

HANGER BALL GROUND WIRE (GREEN)

OUTLET BOX

BLACK SUPPLY WIRE

BLACK FAN WIRE

BLACK/WHITE RECEIVER WIRE

BLUE FAN WIRE

BLUE RECEIVER

WIRE

 

 

OPEN

 

 

 

PORTION OF

SUPPLY GROUND

 

RECEIVER

 

HERE

 

WIRE (GREEN OR

 

 

 

BARE)

 

 

 

RECEIVER

 

 

 

WHITE SUPPLY

 

 

BLACK RECEIVER WIRE

WIRE

 

 

WHITE RECEIVER WIRE

 

 

 

 

CEILING COVER

 

WHITE FAN WIRE

Figure 12

 

 

 

WIRE CONNECTOR

 

RECEIVER

 

5. Lift the ceiling cover up to the threaded

 

 

studs and turn until the studs protrude

 

 

 

 

 

 

through the holes in the ceiling cover

 

BLACK SUPPLY

 

(Figure 14).

WHITE

WIRE

 

6. Secure the ceiling cover in place by

RECEIVER

 

WHITE

WIRE

 

sliding lockwashers (supplied) over the

 

SUPPLY

BLACK RECEIVER

 

WIRE

threaded studs and installing the two

WIRE

 

 

knurled knobs (supplied). (Figure 14).

BLACK/WHITE

 

BLUE RECEIVER

RECEIVER WIRE

Tighten the knurled knobs securely

 

 

WIRE

until the ceiling cover fits snugly against

WHITE FAN WIRE

BLUE FAN WIRE

 

the ceiling.

 

 

 

BLACK FAN WIRE

Figure 13

3. After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the other inside of the outlet box.

4. Screw the two 1-1/4” threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 11).

1-1/4"

 

THREADED

 

STUD (2)

 

#8 EXTERNAL

CEILING

TOOTH

COVER

LOCKWASHER (2)

#8-32 KNURLED

 

KNOB (2)

Figure 14

!WARNING

To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.

10

UL Model No.: CF244 & CF252

Page 10
Image 10
Emerson CF244CRM00, CF244WW00, CF244BS00, CF244ORB00, CF252WW00, CF252CRM00 Lift the ceiling cover up to the threaded