BP7386, CF3400 Corsair 11/25/09 6:20 AM Page 5

If you feel that you do not have enough electrical wiring knowledge or exper- ience, have your fan installed by a licensed electrician.

1. Pull the electrical supply wires through the center opening of the ceiling cover.

!WARNING

Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.

!WARNING

CEILING

COVER

HANGER BRACKET

TAB

MOUNTING SCREW (2)

Figure 2

2. Install the ceiling cover and hanger bracket together onto the outlet box using the two screws supplied with the outlet box. The hanger bracket will nest into the ceiling cover between the raised guides on the bottom surface of the cover. The center hole of the ceiling cover provides visual access to view installation of the outlet box screws into the threaded mounting holes of the box (Figure 2).

!WARNING

To avoid possible fire or shock, do not pinch electrical wires between the ceiling cover and hanger bracket, or the electrical box and the ceiling cover.

3. Pull the electrical supply wires through the opening on the back side of the hanger bracket for installation of the fan’s hanger ball.

4. To prevent scratching the fan assembly, secure the upper motor cover onto a blade flange with masking tape.

5. Carefully lift the fan assembly and install the fan’s hanger ball into the hanger bracket. For added clearance, position the fan’s reverse switch to the side of the hanger bracket during installation.

6. Carefully rotate the fan assembly to engage the hanger ball groove onto the hanger bracket locking tab. When locked in position, the fan will not rotate on the hanger bracket.

To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.

How to Wire

Your Ceiling Fan

NOTE: Pivot the fan on its mounting ball to improve access to the top of the motor when making electrical con- nections with supply wires (Figure 3).

1. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation) with wire connector supplied. (Figure 3.)

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

GREEN GROUNDING LEAD FROM

THE HANGER BRACKET

HANGER BRACKET

HANGER BALL

GREEN GROUNDING

LEAD FROM THE

HANGER BALL

Figure 3

5

Model No.: CF3400

Page 5
Image 5
Emerson CF3400AP, CF3400ORH owner manual How to Wire Your Ceiling Fan