15.Install two 60-watt (maximum) candelabra base light bulbs into the light fitter sockets (Figure 8).

16.Remove the finial nut and outer bowl cap from the light fitter (Figure 8).

17.Pass the fan switch chain through the cut-slotted hole in the bowl cap (Figure 8).

!WARNING

To avoid possible fire hazard, do not exceed wattage indicated on the fitter.

FAN SWITCH

CHAIN

60-WATT

CANDELABRA BASE BULBS (2)

LIGHT FITTER

BOWL CAP

THREADED NIPPLE

GLASS BOWL

OUTER BOWL

CAP

FINIAL NUT

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.

!WARNING

To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local Codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

Figure 8

PENDANTS (2)

LIGHT SWITCH CHAIN

!WARNING

To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.

18.Position the glass bowl over the threaded nipple and seat bowl on bowl cap (Figure 16). Pass the fan pull chain through the bushing in the outer bowl cap and install the cap on the threaded nipple. Install nut finial finger tight.

CAUTION

Be sure that the fan switch chain does not make contact with the light bulbs. If necessary reposition the light fitter to avoid the fan switch chain from touching the light bulbs.

19.Install pendants onto light fixture chain and fan switch chain using couplings provided.

NOTE: It is advisable to periodically check the tightness of the finial.

20.You have now completed the assembly of your new ceiling fan. You can now proceed with hanging and wiring your fan.

Installing The

Hanger Bracket

!WARNING

The fan must be hung with at least 7' of clearance from floor to blades (Figure 9).

7'

MIN.

Figure 9

FLOOR

 

6

U.L. Model No.: CF701

Page 6
Image 6
Emerson CF701WW00, CF701ORB00, CF701BS00 owner manual Electrical Requirements, Installing Hanger Bracket