WARNING:

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION:

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SER- VICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user to the pres- ence of important operating and maintenance (servicing) instructions in the literature accom- panying the appliance.

LASER SAFETY

This unit employs a laser. Only a qualified service person should remove the cover or attempt to service this device, due to possible eye injury.

CAUTION: USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN

THOSE SPECIFIED HEREIN MAY RESULT IN HAZARDOUS RADIATION EXPOSURE.

CAUTION: VISIBLE AND INVISIBLE LASER RADIATION WHEN OPEN AND INTERLOCK DEFEATED. DO NOT STARE INTO BEAM.

LOCATION: INSIDE, NEAR THE DECK MECHANISM.

FCC WARNING- This equipment may generate or use radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modification is made.

RADIO-TV INTERFERENCE

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installa- tion. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

1)Reorient or relocate the receiving antenna.

2)Increase the separation between the equipment and receiver.

3)Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

4)Consult the dealer or an experienced radio/TV technician for help.

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

CAUTION: TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT.

ATTENTION: POUR ÉVITER LES CHOC ÉLECTRIQUES, INTRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRESPONDANTE DE LA PRISE ET POUSSER JUSQU’AU FOND.

– 2 –

EN

1L25

Page 2
Image 2
Emerson EWD2003 owner manual Laser Safety

EWD2003 specifications

The Emerson EWD2003 is a cutting-edge temperature control device designed to enhance monitoring and management in industrial environments. Known for its reliability and precision, this device is utilized in a variety of applications, including HVAC systems, food processing, and environmental monitoring.

One of the standout features of the Emerson EWD2003 is its robust temperature sensing capabilities. It employs advanced sensor technology, which ensures accurate readings and responsiveness to temperature fluctuations. The device can accommodate various sensor types, such as thermocouples and RTDs, making it versatile and adaptable to differing setups.

The EWD2003 supports a broad temperature range, making it suitable for both low and high-temperature environments. Its digital display provides real-time data, allowing users to monitor conditions at a glance. Additionally, the device includes built-in alarm functionalities that alert users to any temperature deviations beyond preset thresholds, ensuring proactive management of potential issues.

Connectivity is another significant technology feature of the Emerson EWD2003. With options for both wired and wireless communications, the device can seamlessly integrate into existing monitoring systems. It supports protocols like Modbus, making it compatible with various industrial automation systems. This connectivity enhances data logging, enabling users to track historical trends and make informed decisions based on empirical data.

The EWD2003 also emphasizes user-friendliness. Its intuitive interface simplifies setup and configuration, reducing installation time. The device can be tailored to fit specific user needs, with programmable settings that allow for customization based on the requirements of the application.

In terms of characteristics, the Emerson EWD2003 is constructed for durability. Its robust design ensures it can withstand harsh industrial environments, while the quality components contribute to a longer lifespan. The device operates with energy efficiency in mind, reducing operational costs for businesses.

In conclusion, the Emerson EWD2003 stands out in the market for temperature control solutions. Its combination of accurate sensing, extensive connectivity options, user-friendly interface, and robust design makes it an ideal choice for industries that require precise temperature management. Whether for critical process monitoring or routine temperature checks, the EWD2003 is engineered to meet the demands of modern industrial applications.