Mounting the Sensor
Mounting the electronics of high-temperature and extreme high-temperature sensors
High-temperature and extreme high-temperature F-Series sensors come with a 32″ (812 mm) pre-installed flexible conduit. This conduit is required for agency approval.
A factory-supplied Model 1700/2700 transmitter, core processor, or junction box is connected to the end of the flexible conduit. Mount the electronics to a wall or instrument pole using the supplied bracket (Figure 10).
Figure 10 Electronics mounting for high-temperature F-Series sensors
Mounting bracket (wall mount)
Mounting bracket (instrument pole)
Use 4 × 5/16″ (8 mm) bolts to secure the bracket to a wall
Use 2 × 5/16″ (8 mm) U-bolts to secure the bracket to an instrument pole
Slide the electronics into the bracket groove.
Secure the electronics to the bracket with the 4 #10 screws.
14 | Sensor Installation: F-Series |